Chain-of-custody: TEM analysis, PS 234M, May 19 2002

Machine-extracted title · confidence 40%

Chain-of-custody for TEM asbestos analysis, PS 234M, May 19, 2002.

NYC-WTC_000264616–000264634
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Associates 104 East 25 Street, New York, NY 10010 Phone; (212)353-8280 Fax: (212)353-8306

Attn: Mr. Bernard Orlan Received: 5/19/02 7:00:00 PM N.Y.C. Board of Education ATC Group#: 7798 28-11 Queens Plaza North Analysis Date: 5/19/02 Long Island City, NY 11101 Fax: (212) 475-4122 Phone: (212)477-8941 Project: NYC-BOE PS 234M Project#: 14584-1823

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos ^Structures Sensitivity Concentration Sample l^olume Analyzed Asb Type(s) O.Sfi-5 Sp (S/cc) (S/mm^) (S/cc) Notes

01 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7798 -!

02 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7798 -2

03 1912.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7798 -3

04 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7798 -4

05 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7798 -5

06 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7798 -6

07 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7798 -7

MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.

Analyzed by. Approved by.

Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboiatory personnel. This lab iVohty responsible for data repotted in stnjctures/mm’ This report may not be reproduced, except in lull, without written approval by ATC Associates Inc, This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.

Accredited for NVLAP PLM/TEM #101187-0. NY State ELAP #10879

Pape I of 2

CONFIDENTIAL, CITY_21MC1OO_OO34O3498 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000264616

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000264616Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000181731

Documentation of asbestos fiber analysis by TEM performed on samples from P.S. 234M received on May 15, 2002.

Similar indexed content

NYC-WTC_000264535

Chain-of-custody for asbestos TEM analysis samples from PS 234M, May 2002.

Similar indexed content

Compare copies and versions →