ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y, State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/02/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) Kith Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDE) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Projeot/Site; P.S. 234M, 252 Greenwich St., NY, NY TEM Sample No.: 5592 - 59901 Entire School Date Received:10/02/01 Grid Openings Analyzed-.__4

Project Sample Mo.: PS234W-ES-10/2-07 Average Grid Opening: 106.00 urn

Air Volume; 1820 liters Total Area Analyzed: 0.0450 mm2

9 Fi 1 ter Type; MCE 25 min diarr.. , Pore Size: 0.45 um Analytical Sensitivity: T-Kd

22.2 s/mmR Effective Area; 385 m^ 0,0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct. >«5um Struct/Tnm2 Struqt/cc ncrm/mS

Qirysotile Asbestos 0 0 ^0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 •0 0 0 0 0.0 0.0000 0

Ambiguous v 0 0 0. : 0 ; -0■; -G 0.0 0.0000 0 ’

Total asbestos (includes ambiguous structures) 0 0 0.0 O.OOOD 0 Non-Asbest^s ’ 0 0 0 0 0 0.0 N/A No Identification 0 0 0 0 0 0.0 N/A tS_.'

Totals (All Structures') 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbesto.s fiber i.d. (EDS/SAED) : None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in. co.mpliance .with’ the. quality specified for the method.

Tknalyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy to si;

CONFIDENTIAL, CITy_21MC100_003467272 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000262769

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000262769Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →