NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE; 03-11-02
CLIENT: NYC BOE
PROJECT ADDRESS: M833/100 Trinity Place
NY, NY 10006
PROJECT NO; 41617-0563
SAMPLED BY: C. Mathew
SAMPLE DATE: 03-09-02
DATE RECEIVED: 03-09-02
DATE ANALYZED: 03-09-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANAI YSIS RFSllT.TS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(Pg/ft^ (pg/tf)
01 9718 1st Floor Lobby Outside Auditorium fl 14.6 9.0
02 9718 Cafeteria by Stairs Floor 15.1 9.0
03 9718 Auditorium by Stage Floor 16.9 9.0
04 9718 Classroom 607 Floor <9.0 9.0
05 9718 Classroom 410 Floor <9.0 9,0
06 9718 3rd Floor Hallway <9.0 9.0
07 9718 5th Floor Hallway <9.0 9.0
08 9718 7th Floor Hallway <9.0 9.0
09 9718 9th Floor Hallway by 933 <9.0 9.0
10 9718 Office 933 Middle Office Window Sill <9.0 9.0
11 9718 Blank <9.0 ng 9.0 ng
NOTE I :
THE REPORTING LIMIT (RL) IS 18.0 ug
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 pg ft/ Window sills 250 pg/fp.
Window wells 400 pg'ttl Exterior surfaces 800 pg ftl
NOTES:
Blank units are in pg
CONFIDENTIAL, CITY_21MC100_003463287
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000259755