IAQ report, High School of Economics and Finance, May 2002

Machine-extracted title · confidence 34%

Indoor air measurements collected May 20, 2002 for BOE IAQ program.

NYC-WTC_000259425–000259428
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan May 21, 2002 Indoo' Air Quality Assessment Page 4 H.S. c f Economics and Finance (M833) ATC Project No. 15-19125-02.91 a 24-hour average.

TVOC Concemration

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC conceitration was also 0.0 ppm.

OBSIRVATIONS

During this assessment, Al’C noted the following: • The interior of the building appeared clean and free of dust and debris; • The building was occupied at the lime of the assessment; • No smoke odor was detected in the building;

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. In Joor concentrations of CO and TVOCs were below applicable standards and guidelines. 2. Twenty-one (21) of the indoor measurements for temperature collected were above and twenty-two (22) measurements were below the range of 73 to 79°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season. 3. Si;<ty-six (66) of the indoor measurements for relative humidity were below the ASHRAE recommended range of 30 to 60 percent for occupant comfort. 4. Sixteen (16) of the indoor measurements for CO2 were above the ASHRAE Standard 62- 1999 recommended maximum concentration of <700 ppm above the background level. 5. Two (2) of the indoor measurements for respirable particulates were above the NPAAQS of 65 jig/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in ae 'odynamic diameter. Three (3) of the indoor measurements were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.

It is oar pleasure to provide these indoor air quality services to the New York City Board of Educa ion. If you have any questions about this report, please call (212) 353-8280, extension 211 or212.

Sincerely, Fl TC ASSOCIA TES INC. Rcyi

. r£ /viann s Efstathiou Jame's R. Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene

Attach ment

CONFIDENTIAL, CITY_21MC100_0 03462621 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000259428

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000259428Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000259200

Indoor air quality measurements taken April 18, 2002 for BOE program.

Similar indexed content

NYC-WTC_000259487

ATC summary of IAQ measurements collected June 4, 2002 at the school.

Similar indexed content

NYC-WTC_000384991

ATC indoor air quality measurements at the referenced school, May 2002.

Similar indexed content

NYC-WTC_000259515

ATC IAQ measurements report for June 13, 2002 at the school.

Similar indexed content

NYC-WTC_000259196

ATC indoor air quality measurements conducted April 17, 2002 for BOE review.

Similar indexed content

Compare copies and versions →