NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

IAQ report, High School of Economics and Finance, Apr 2002

Machine-extracted title · confidence 41%

Indoor air quality measurements taken April 18, 2002 for BOE program.

NYC-WTC_000259200–000259203
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 19, 2002 Indoor .Air Quality Assessment Page 2 U.S, jf Economics and Finance (M833) ATC Proiect No. 15-19125-0291

The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air qualiy control activities.

EVAUJATIOiN CRITERIA

Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:

yeniilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), America! Industrial Hygiene Association (AIHA).

Tablt 1 lists target guidelines for the parameters that ATC evaluated during this investigatior.. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.

TABLE 1 TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVAI HATED

PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Car ion Dioxide <700 parts per million (ppm) ASHRAE 62 (CC-2) above background level Caraon Monoxide 9 ppm ASHRAE 62 (adopted from (CC.) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Parrculates (PM2.5) of air (pg/m3) 24-hour average 40 pg/m^ 24-hour average USEPA - Recommendation for children / sensitive individuals Tenperature Summer; 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 - 60 % ASHRAE 55 Total Volatile Organic Compounds ] ppm AIHA (TA^OC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIH/i = American Industrial Hygiene Association

CONFIDENTIAL, CITY_21MC1OO_OO3462299 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000259201

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000259201Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000259196

ATC indoor air quality measurements conducted April 17, 2002 for BOE review.

Similar indexed content

NYC-WTC_000259208

Report of indoor air quality measurements collected April 22, 2002 for BOE.

Similar indexed content

NYC-WTC_000259244

ATC report of IAQ measurements collected April 25, 2002 for BOE.

Similar indexed content

Compare copies and versions →