NYC-WTC_000258831
TEM asbestos analysis results for BOE project at H.S. [name], June 18-19, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis results for BOE project at H.S. [name] [name], June 2002.
NYC-WTC_000258804–000258806OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax:(212)353-8306
Attn: Mr. Bernard Orlan Received: 6/15/02 4:00:00 PM N.Y.C. Board of Education ATCGroup#: 8119 28-11 Queens Plaza North Analysis Date: 6/15/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941 Project: H.S. Of Economics And Finance 100 Trinity Place, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area /Son Asbestos # Structures Sensitivity Concentration Sample yolume Analyzed Asb Typefs) 6.5m-5 5m (S/cc) (S/mm^) (S/cc) Notes
03 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048 8119 -/
04 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048 8//9 -2
05 1808.00 0.0450 0 None Defected 0 0 0.0047 <22.24 <0.0047 8//9 .3
06 1816.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 S//9 -4
07 1816.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 S//9 -5
08 1824.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 81/9 -6
09 1808.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 8/19 -7
ROMAN PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: iproved by:
Disdaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume by non-laboratory personnel. This lab iWfly responsible for data reported in structuresimml This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLMTEM #101187-0, NY State ELAP #10879
Page I of 3
CONFIDENTIAL, CITY_21MC100_003461565 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000258804
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000258831
TEM asbestos analysis results for BOE project at H.S. [name], June 18-19, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000374007
Asbestos TEM results for BOE project, June 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373796
TEM analysis by TEM for HS project 7750, AHERA method.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000254349
TEM asbestos analysis results with chrys, site 100 Trinity Place, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410323
Asbestos fiber TEM analysis by AHERA method for school location, May 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000213417
Technical data sheet showing asbestos fiber counts per cubic centimeter from TEM analysis performed under AHERA standards on May 8, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373811
TEM asbestos analysis conducted under AHERA; samples received May 18, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373947
TEM asbestos analysis results for AHERA-compliant sampling.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410330
Asbestos TEM analysis performed for DOE project at school, May 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000402890
Asbestos TEM analysis performed; AHERA compliance; data dated Mar 19, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373768
TEM asbestos analysis by AHERA method for HS project, 7717 data.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000374043
TEM asbestos analysis with AHERA methodology for project site.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000258831
TEM asbestos analysis results for BOE project at H.S. [name], June 18-19, 2002.
Similar indexed content
NYC-WTC_000374007
Asbestos TEM results for BOE project, June 2002.
Similar indexed content
NYC-WTC_000373796
TEM analysis by TEM for HS project 7750, AHERA method.
Similar indexed content
TEM asbestos analysis results with chrys, site 100 Trinity Place, Apr 2002.
Similar indexed content
NYC-WTC_000410323
Asbestos fiber TEM analysis by AHERA method for school location, May 2002.
Similar indexed content