NYC 9/11 Public Portal Document
Pace Analytical Services, Inc
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel 612-607-1700
Fax 612-607-6444
Client - ATC
Client's Sample ID ATC-0214-M894-DX2
Lab Sample ID 103331823
Filename F20307A_09
Injected By MRO
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/14/2002
ICAL Date 01/24/2002 Received 02/18/2002
CCal Filename(s) F20306B_14 & F20307A_16 Extracted 02/28/2002
Method Blank ID BLANK-1489 Analyzed 03/07/2002 20:45
Native Cone EMPC LRL Internal ng'S Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0 00200 2,3,7,8-TCDF-13C 2.00 75
Total TCDF 0.020 0.00200 2,3,7,8-TCDD-13C 2.00 66
1,2,3,7,8-PeCDF-13C 2.00 84
2,3.7.8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 79
Total TCDD 0.056 0.00200 1,2,3,7,8-PeCDD-13C 2.00 79
1,2,3,4,7,8-HxCDF-13C 2.00 100
1,2,3.7,8-PeCDF ND 0.01000 1,2,3,S,7,8-HxCDF-13C 2,00 66
2,3,4.7,8-PeCDF ND 0.01000 2,3.4,6,7,8-HxCDF-13C 2.00 81
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 82
1,2,3,4,7,8-HxCDD-13C 2 00 89
1,2,3,7,8-PeCDD ----- 0.013 0.01000 I 1,2,3,6,7,8-HxCDD-13C 2.00 79
Total PeCDD 0.130 —- 0 01000 1,2,3,4,6,7,8-HpCDF-13C 2 00 70
1,2,3,4,7,8,9-HpCDF-13C 2 00 64
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 67
1,2,3,6,7,8-HxCDF ND 0 01000 OCDD-13C 4.00 65
2,3,4,6,7.8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.022 0.01000 J 1,2,3,7,8.9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 0.049 0.01000 J 2,3,7,8-TCDD-37CI4 0.20 77
1,2,3,6,7,8-HxCDD 0 014 0.01000 J
1,2,3,7,8,9-HxCDD 0.015 0.01000 J
Total HxCDD 0.630 0.01000
1,2,3,4.6,7,8-HpCDF 0.040 0.01000 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence 0.012 ng/m2
Total HpCDF 0.083 0.01000 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.250 0.01000
Total HpCDD 0.910 0.01000
OCDF 0.055 0.02000 J
OCDD 0 830 0.02000
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additonal analysis * = See Discussion
Report No.. ..02-1054210
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full.
Without thP wnttAn rnncipnt nf Par© Analxr+iraJ lnr«
CONFIDENTIAL, CrTY_21MC100_003459604
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000257131
OCR can misread numbers and units. Confirm readings against the page image before using them.