NYC 9/11 Public Portal Document
Scope of Work
ATC Associates, Inc (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect dust wipes to be analyzed for lead content after a lead-m-dust cleanup is
completed m rooms 207, 606 and the cafeteria
ATC’s representative Ms Mariana Medinets visited the H S of Economics & Finance
(M833) located at 100 Trinity Place, New York, NY on January 16‘\ 2002. Dust wipes
to be analyzed for lead content were collected from rooms 207, 606 and the cafeteria after
the lead-m-dust cleanup is completed as specified by the New York City Board of
Education Environmental Health & Safety Unit and m accordance with HUD protocols.
LEAD-IN-D UST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173 14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-m-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels) As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below
For Window wells 400 Lig/lr
For Windowsills. 250 ng/ft-
For Floors 40 gg/tf
Sampling Methodology
ATC provided all laboratory analytical services in support of tlus limited inspection ATC
IS certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
(Laboratory ID Number 10879) The laboratory utilizes tire United States Environmental
Protection Agency analysis method number SW846-7420 and the National Institute of
Occupational Safety and Health metliod number 7082M.
The lead-m-dust samples were obtained by gently wiping a pre-measured surface area
with non-alcohol moistened towelettes ATC’s representative wore disposable gloves, a
new glove was worn with each new sampling procedure, and care was taken to avoid
contamination of the towelette and collection vial Towelettes were then placed into
50ml plastic vials and immediately sealed. The chain of custody form was completed and
documents the measurement of the area sampled
Results of Dust Wipe Sampling
Three (3) dust wipe samples were collected from rooms 207, 606 and the cafeteria after the
lead-m-dust cleanup is completed. Laboratory analysis is shown that all dust wipe samples