Indoor air quality report, M833, Feb 2002

Machine-extracted title · confidence 46%

Indoor air quality measurements conducted at the referenced school; Feb 2002.

NYC-WTC_000257031–000257034
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr Bernard P Ori an February 28, 2002 Indoor Air Quality Assessment Page 4 H S of Economics and Finance (M833) ATCProiectNo 15-19125-0291

TVOC Concentration

TVOCs were not detected anywhere inside the building (0 0 ppm) Tire outdoor TVOC concentration was also 0 0 ppm

OBSERVATIONS

During this assessment, ATC noted the following • The interior of the building appeared clean and free of dust and debris, • The building was occupied at the time of the assessment, • No smoke odor was detected in the building,

FINPINGS

Based on the real-time measurements, the following findings are presented

1. Concentrations of respirable particulates, CO, CO2 and TVOCs, were within applicable standards and guidelines 2. Twenty-two (22) temperature measurements were below' the range of 68 to 75°F (at 50 percent relative humidity recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions) 3. Two (2) of the relative humidity measurements were within the ASHRAE recommended range of 30 to 60 percent for occupant comfort All other relative humidity measurements were below the ASHRAE recommended range

It IS our pleasure to provide these indoor air quality services to the New York City Board of Education If you have any questions about this report, please call (212) 353-8280, extension 261 or 212

Sincerely, Reviewed by A rc ASSOCIA TES INC.

A Andreas C Andreou James R Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003459424 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000257034

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000257034Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297663

Indoor air quality measurements report dated Feb 5, 2002 for the referenced school.

Similar indexed content

Compare copies and versions →