NYC-WTC_000249395
PACE report header stating lab analysis and project details for sample set 19125-0279.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory analysis report for the M833 project; includes lab methods and results.
NYC-WTC_000256996–000257010OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pace Analytical Services, Inc. 1700 Eim Street, Suite 200 'ace Analytical" Minneapolis, MN 55414 Phone 512.607 1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax 512 607 6444
I PROJECT: PCDD/PCDF ANALYSES DATE: February 1, 2002
PAGE: 3 REPORT NO: 02-1053169
PCDD/PCDF Analyses
Each sample extract was analyzed for the presence of PCDDs and PCDFs using combined capillary column gas cfwomatography/high resolution mass spectrometry (HRGC/HRMS). The i instrumentation consisted of a Hewlett Packard Model 6890 gas chromatograph interfaced to a Micromass Ultima high-resolution mass spectrometer. The capillary column was interfaced directly into the ion source of the mass spectrometer, thus providing the highest possible sensitivity while minimizing degradation of the chromatographic resolution.
The mass spectrometer was operated in the electron impact ionization mode at a mass resolution 3 of 10,000-11,000 (M/AM, 10 percent valley definition). This resolution is sufficient to resolve most interferences, such as PCBs, thus providing the highest level of confidence that the detected P levels of PCDDs are not false positives resulting from interferences. Typical operating parameters LJ for the HRGC/HRMS analyses are summarized in Table 2.
The data were acquired by selected-ion-recording (SIR) monitoring of the groups of ion masses ' described in USEPA Method 23. The five groups corresponded to the tetrachlorinated through octachlorinated congener classes. Each group contained two ion masses for the PCDDs, two ion masses for the PCDFs, the corresponding ion masses from the two isotopically labeled internal standards, and the ion mass characteristic of the polychlorinated diphenylether (PCDPE) which, if present, could cause false responses in the dibenzofuran channels.
' Each group of ion masses also contained a lock mass which was monitored during the analyses to detect suppressive interferences. It is particularly important to detect this type of interference since It can cause the quantification of congener class levels to be artificially high if it occurs during the elution of an internal standard or low if it occurs during the elution of the native analytes.
;l
REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc
CONFIDENTIAL, CITY_21MC100_003 459333 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000256999
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000249395
PACE report header stating lab analysis and project details for sample set 19125-0279.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000395804
Chain-of-Custody data sheet for Pace Analytical project 6526-0279.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396362
Pace Analytical chain-of-custody form accompanying a 31-page lab report package.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396324
Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396381
PACE chain-of-custody accompanying a 30-page Pace Analytical report package.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256605
PACE Analytical lab report for project [name], 23 pages, with standard methodologies.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000395785
Chain-of-Custody document for Pace Analytical lab data and pages count.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000395823
Pace Analytical chain-of-custody form, project data and page count note.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256565
PACE Analytical report/dossier with NYC project details and determinations.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310760
Attachment: analytical laboratory report for PCBs and PCDDs/PCDFs, NYC-WTC file.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256588
PACE Analytical lab report on Project: [name], with general test details and 23-page document referenced.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240837
Series of Pace Analytical lab pages including C/F levels; NYC-WTC dataset.
9 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000396324
Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000395804
Chain-of-Custody data sheet for Pace Analytical project 6526-0279.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310760
Attachment: analytical laboratory report for PCBs and PCDDs/PCDFs, NYC-WTC file.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000249395
PACE report header stating lab analysis and project details for sample set 19125-0279.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000395823
Pace Analytical chain-of-custody form, project data and page count note.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396362
Pace Analytical chain-of-custody form accompanying a 31-page lab report package.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
PACE report header stating lab analysis and project details for sample set 19125-0279.
Similar indexed content
Chain-of-Custody data sheet for Pace Analytical project 6526-0279.
Similar indexed content
Pace Analytical chain-of-custody form accompanying a 31-page lab report package.
Similar indexed content
Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.
Similar indexed content
PACE chain-of-custody accompanying a 30-page Pace Analytical report package.
Similar indexed content