NYC 9/11 Public Portal Document
Mr Bernard P Orlan Janiiaiy 22, 2002
Wipe Sampling for PCBs and PAHs Page 2
H S of Economics & Finance (833M) ATCProiectNo 15-19125-0291
WIPE SAMPLING RESULTS
ATC submitted seven samples for PCBs and PAHs to PSC for analysis A blank was also
submitted. A copy of the laboratory report is provided m the Attachment Samples were taken
from surfaces throughout the building The sample area for each wipe sample was 100 square
centimeters (lOOcm^). The areas sampled were
• Mam lobby floor,
• Room 304, desk;
• 5th floor Staircase A,
• 7th floor hallway by the bridge;
• 8th floor, Kitchen counter;
• Room 906, windowsill;
• Room 1006, table.
Each sample was analyzed for seven (7) PCB compounds and sixteen (16) PAHs (see
attachment) The PCB and PAH results of all samples collected were belorv the reporti/ig limits
of 2.0 and 5.0 micrograms/sample (ug / sample) respectively.
Currently, the Environmental Protection Agency spill clean-up standard for PCBs on non-porous
surfaces is 10 micrograms per 100 square centimeters or less (<10ug/100cm2) as stated in 40
CFR 761 No regulatory standards have been established for PAHs on surfaces.
It IS our pleasure to provide these indoor environmental services to the New York City Board of
Education If you have any questions about this report, please call (212) 353-8280, extension
212 or 261.
Sincerely,
/I TC ASSOCIA TES INC.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_0 03459262
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000256929
OCR can misread numbers and units. Confirm readings against the page image before using them.