NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air samples for PCB PAHs, Jan 2002

Machine-extracted title · confidence 40%

Report of PCB and PAH air sample results at a NYC high school.

NYC-WTC_000256923–000256924
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 wwwatc-enviro com 212 353 8280 Fax 212 353 8306 ASSOCIATES INC

January 23, 2002

Mr. Bernard P Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Air Samples for Polychlorinated Biphenyls High School of Economics and Finance ATC Project No. 15-19125-0291

Dear Mr Orlan-

ATC Associates Inc (ATC) is pleased to provide this report of the results of air samples for polychlorinated biphenyls (PCBs) collected on January 22, 2002, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building

SCOPE OF WORK

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office, collected the samples.

The samples were collected using glass fiber filters and Florisil® tubes cormected in series to battery-powered sampling pumps set at a flow rate of 0.2 liters per minute. The sampling time was ten (10) hours. The samples were analyzed by PSC Analytical Services, Inc. (PSC), an American Industnal Hygiene Association-accredited laboratory in Reading, PA Analysis was performed according to NIOSH Method 5503 (gas chromatography/electron capture detector)

The sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected

SAMPLING RESULTS

ATC submitted nine (9) samples for PCBs (plus one blank) to PSC for analysis Each sample was analyzed for seven (7) PCBs with different chlorine contents Copies of the laboratory reports are provided in the Attachment

Samples were collected from locations throughout the building. The sampling locations were Outdoors at the Main Entrance, the Mam Lobby, 3^^ floor Hallway by Stair B, 5th floor by stair A, floor Hallway by the bndge, 8^^ floor Kitchen, Room 906, Room 1006 and the Roof by the air intake.

CONFIDENTIAL, CITy_21MC100_0 03459254

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000256923

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000256923Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297565

Lab report of PCB air samples collected December 30, 2001 at the BOE school.

Similar indexed content

NYC-WTC_000310791

Air sampling results for PAHs at High School of Economics & Finance (M833), Jan 22, 2002.

Similar indexed content