Pace Analytical Services, Inc. 17G0 Elm Street, Suite 200 Minneapolis, MN 55414 ! www.pacelabs.conn REPORT OF: CHEMICAL ANALYSES Phone: 612.S07.1700 Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: December 3, 2001

ISSUED TO: ATC Associates REPORT NO: 01-1051099 Attn: Mr. Jim Cohn 104 East 25th Street, 10th Floor New York, NY 10010

INTRODUCTION

This report presents the results from the analyses performed on four samples which were submitted by a representative of ATC Associates. The samples were analyzed for the presence or absence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) using a modified version of USEPA Method 8290 as described below.

SAMPLE IDENTIFICATION

Client ID Sample Type Date Received Pace ID

ATC-1 114-DX-01 Wipe 11/15/01 103142899 ATC-1 1 14-DX-02 Wipe 11/15/01 103142907 ATC-11 14-DX-03 Wipe 11/15/01 103142915 : ATC-11 14-DX-04 Wipe 11/15/01 103142931

METHODOLOGY

Sample Extraction

Each sample was spiked with ^^Ci2-labeled PCDD/PCDF internal standards (Table 1) and extracted with toluene in a Soxhlet extractor. The extract was quantitatively transferred to a Kuderna-Danish concentrator, concentrated, and solvent exchanged to hexane. The hexane extract was then spiked with 2,3,7,8-TCDD-^^C14 enrichment efficiency standard (Table 1) and processed through the analyte enrichment procedures described below.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC100_003458737 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000256566

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000256566Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348993

Determination of PCDD/PCDF levels for project: World Trade Center.

Similar indexed content

Compare copies and versions →