104 East 25th Street 10th FL New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

November 6, 2001

Mr. Bernard P. Orlan Director, Environmental Health and Safety 7 New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re; Air Sampling for Silica Dust Stuyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan;

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica- contaming dust conducted on October 18-19 and 24-25, 2001, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to the parents’ association. The results of samples collected on October 31, 2011, are not yet available.

ATC collected a total of twenty (20) samples for respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. Six (6) samples were collected on October 18"' and six were collected on October IQ*. Four samples were collected on October 19* and 25*. In addition to the indoor samples, one sample was collected outdoors on October 18* and 25*. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. Four blank filters were also submitted. Analysis was performed by x-ray diffraction according to NIOSH Method 7500. A copy of the analytical report is attached.

Silica was found above the limits of detection in only one of the twenty samples. This was the sample (#ATC-1O24-S1) collected on October 24* in the 9* floor hallway by the elevator. This sample contained 0.017 milligrams of silica per cubic meter of air (mg/m’). The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) for silica- containing dust is based on the percent of quartz (SiO; i found in the dust, the higher the percentage of quartz, the lower the PEL. The formula for calculating the PEL is found in 29 CFR 1910.1000, Table Z-3. The formula is; 1 Omg/m^ %SiO2 + 2

The amount of quartz in Sample #ATC-1O24-S1 was 13%, therefore the PEL for this dust would be: lOmg/m^ 0.67 mg/m^ 13 + 2

The silica concentration in this sample was 0.017 mg/mg\ which is 2.5% of the calculated PEL.

CONFIDENTIAL, CITY_21MC1OO_OO3458647 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_00025651 1

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000256511Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000226997

Report letter from ATC Associates detailing air sampling for silica-containing dust conducted at Stuyvesant High School.

Similar indexed content

Compare copies and versions →