sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.
EVALUATION CRITERIA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:
Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal En vironmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIIIA),
Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.
TABLE I TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED
■PAJL^E^Ri.yU;, iTARGLT:LEyEL .<(.27 (f, 4;“ ORGAN IZAirON Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm. • ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2.5) of air (p.g/m3) 24-hour average Temperature Summer: 73-79°F at 50% RH ASHRAE55' Winter; 68-75°F at 50% RH Relative Humidity 30 -60 % ASHRAE 55 Total Volatile I ppm Organic Compounds AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association
Real-Time Environmental Measurements
ATC collected one hundred and twenty-six (126) sets of real-time environmental measurements consisting of one hundred and twenty-four (124) in the school building and two (2) outdoors. All ten floors of the school were surveyed. These results are described below. Field data sheets are found in Attachment 1. Readings began at 8:10 A.M. and concluded after 3:05 P.M.
CONFIDENTIAL, CITY_21MC100_003457200 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000255548
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000255518
IAQ measurements reported for Stuyvesant High School; December 10, 2001.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255522
Indoor air quality measurements at Stuyvesant High School, December 12, 2001.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273995
December 2001 IAQ measurements at Stuyvesant High School with BOE contact.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401506
Indoor air quality measurements collected December 17, 2001 at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401450
Indoor air quality measurements conducted December 10, 2001 at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255564
Indoor air quality measurements collected on December 17, 2001 at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274045
December 20, 2001 IAQ measurements at Stuyvesant High School for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401484
Indoor air quality measurements collected December 12, 2001 at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273973
Memorandum regarding indoor air quality measurements at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274012
December 2001 IAQ measurements at Stuyvesant High School with BOE references.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401524
Indoor air quality measurements conducted December 17–18, 2001 at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401541
IAQ measurements reported for December 24, 2001 at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000401450
Indoor air quality measurements conducted December 10, 2001 at Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255518
IAQ measurements reported for Stuyvesant High School; December 10, 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401484
Indoor air quality measurements collected December 12, 2001 at Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274012
December 2001 IAQ measurements at Stuyvesant High School with BOE references.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401739
Indoor air quality report for Stuyvesant High School, January 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255564
Indoor air quality measurements collected on December 17, 2001 at Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
IAQ measurements reported for Stuyvesant High School; December 10, 2001.
Similar indexed content
NYC-WTC_000255522
Indoor air quality measurements at Stuyvesant High School, December 12, 2001.
Similar indexed content
December 2001 IAQ measurements at Stuyvesant High School with BOE contact.
Similar indexed content
NYC-WTC_000401506
Indoor air quality measurements collected December 17, 2001 at Stuyvesant High School.
Similar indexed content
Indoor air quality measurements conducted December 10, 2001 at Stuyvesant High School.
Similar indexed content