Lead-in-dust wipe sampling report, M833

Machine-extracted title · confidence 44%

Limited lead-in-dust wipe sampling report for 100 Trinity Place site.

NYC-WTC_000254571–000254573
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were collected from areas recommended by Parent Association consultant representative Mr Eric Telemaque of EMTEQUE and approved by NYC-BOE and as specified in the sampling protocol for the school. These areas are the following:

• 1” floor lobby outside Auditorium • Cafeteria • Auditorium • Two random classrooms • 3"* floor hallway • 5'*' floor hallway * 7* floor hallway • 9* floor hallway

The purpose of the dust wipe sampling is to determine if dust in the school contains lead. ATC will be repeating this sampling every Saturday as per the recommendation of NYC- BOE. This is the 11”' consecutive week that dust samples were collected from High School for Economics & Finance (M833) to be analyzed for lead content.

ATC’s representative Mr. Chacko Mathew visited High School for Economics & Finance (M833) located at 100 Trinity Place, New York, NY 10006 on May 11^ 2002. Dust wipes to be analyzed for lead content were collected from or within the aforementioned areas indicated to ATC by EMl’EQUE and as specified by the New York City Board of Education Environmental Health & Safety Unit and in accordance with HUD protocols.

LEAD-IN-DUST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (HPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occuned (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For Windowsills: 250 pg/tf For Floors: 40 pg/ft“

Although the lead-in-dust samples collected at High School for Economics & Finance (M833) were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project.

Sampling Methodology f!ig^ for Eeonomios d' Einofico TC I* Tl ( 104 Muy 13. .''1112

CIT Yj2Ql?Elffi)mn)I>Sl331413

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT

NYC-WTC_000254572

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000254572Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180135

Report documenting limited lead-in-dust wipe sampling conducted at the school in May 2002.

Similar indexed content

Compare copies and versions →