ATC Environmental, Inc’. 104 East 25th Street New York, New York 10010

■N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/02/01 ....... ASBESTOS"'FIBER-'-ANALYST'S" "BY'~TRANSMI'S£I'ON~ELECTR'ON MICROSCOPY (TEM') ' With'Fiber identification -by 'Selected-Area -Electron Diffraction ‘(SASD) and 'Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register (40 GFR, Part 763), Vol. 52, No. 210, October 30; 1987

Sarnple Identification Analysis Parameters

• Project/Site; P.S. 234M, ,292 Greenwich 'St. , NY, -NY TEM Sample No.; '5592 - 59910 ...-.~ - Entire .School Date Received: 10/02/01 Grid Openings Analyzed: 4

Project Sample No.: PS234M-SS-10/2>16 •Average Grid Opening: 106.00 um

Air Volume: 1B2O liters Total Area Analyzed; 0.0450 rnm2

Filter Type: MCE 25 mm diam., Pore Size; 0:45 um Analytical Sensitivity; 22.2 5/nini2 Effective Area: 385 mm2 0■0047 s/cc

FIBROUS PARTICULATES ANALYZED ■ Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct> Struct. >=5um Struct/mm2 Struct/cc nqm/m3

■','1 Chrysotile Asbestos , 0- ■ =0 £31' ..^0, • 0 ■ -■6.0 o.boob'-- 0

Amphibole Asbestos 0 0 0 0 0-- 0.0 0.0000 0

Ambiguous '■ •; -0 • r9<' 0 9"'°' •. o.-oooo

Total asbestos’''(includes ambiguous’structures'')i''- ? • .0 ■0 0.0 0.0000 0/ ■ ?/■/ (iHon^Asbis^os'h;. ■I'/’,,:. J’'' ■■: o' 0,' . .Xdood'"'/'/' '? n/aI ' No Identification 0 , 0 ‘ ■^6- ■ 1 ■ ■'.'■0 .o.o’ .^'$000’.:" 'k/a’'

Total's (All Structures) ' ’• . ,0 o' 0.0 0.0000 N/A The estimated uncertainty of this analysis is i standard deviation.

•Non-asbestos fiber i.d. (BDS/SAED): None detected Amphibole Asbestos Type.: None ■ detected.

The Analysis , was carried’ ■out : in. accordance, with the approved TEM method'.’ .' ' 1 'This, laboratory is?' in- compliance.-yi th.-phetguality'specified for. the ..method,

Analyzed 'by : Report Reviewed by:

Marek Peysakhov Michael A..Gorycki, Ph.D. ■;/y/y,f'i./''"'Di're'ctdr ’of' Electron Microscopy ¥1’ ./'• jv 'V:;? 'SSW V CONFIDENTIAL, CITY_21MC100_0 03390293

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000253084

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000253084Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos TEM analysis, PS 234M, Oct 2001

NYC-WTC_000373428

TEM-based asbestos analysis at PS 234M, project site noted; includes transmission electron microscopy and SAED/EDS methods.

Similar indexed content

Compare copies and versions →