TEM asbestos analysis, PS 234M

Machine-extracted title · confidence 41%

TEM analysis with SAED/EDS for PS 234M samples.

NYC-WTC_000253072
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental , Inc. 104 East 25th Street New York, New York 10010

W.Y.C. Board of Education Approved N.Y. State ELAP #10875. 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/-02/O1

------ ASBESTOS-FI-BER ANALYSIS--BY TRANSMI'SS.TGN ELECTRON -MTCROSCOPY (TEM-) With Fiber Identification by Selected-Area .Electron Diffraction ISAED) and Energy-Dispersive X-RAY Spectroscopy lEDS) Method: AHERA Pinal Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Ident'ificstion' Analysis -Parameters

Project/Site: P.S. 23'4M, 292 Greenwich 5t. , NY, ‘NY TEM .Sample No. : -5592 - 59897 Entire School Date Received: 10/02/01 Grid Openings Analyzed:__ 4

Project sample Ko.: PS234M-ES-i0/2-03 Average Grid Opening: 106,00 urn

Air Volume; 1620 liters . Total Area Analyzed: 0.0450 mml

Filter Type; MCE 25 mm diam.. Pore Size: 0?^5 um Analytical Sensitivity: 22.2 s/rom2 Effective Area: 385 nroG 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct. >*’5utn Struct/.Trgn2 Struct/cc nqn/mO

. Chrysotile. Asbestos . 0 0 .0 0 0.0 O.'OOOO, ’0

■ ?:. Amphibole Asbestos- ", 0 0 ■ 0.0 0.0000 _ 0

■'A Amhi^ous 0 .0 /Sits o'.'o 0.0000- > '

•’r,Total asbestos -(includes ambiguous structures). ', j - . - . -7 ■■0 --' . -0 0.0 0.0000' •0 • fe-'s.:,. NonrAsbeStos O' ., 0.,. ... 0,0 ;:£;O.boo23-‘' Identification' ' ■■O.'.'t 0 'i-'O.!.;/' . :0' ' ' „ "■'0 . -- ' ,0.0 .ttioos - K/A. ■' N/A ■ ■ ;<• . Totais (All Structures.)--, 0.0 0.0000 The estimated uncertainty of this analysis is 1 standard .deviation.

Non-asbestos fiber i.d. (EDS/SAED,) ; None detected 2$: Amphibole Asbestos Type: None 'detected' '' '■ •V The .Analysis ; was' carried put. in' acco.rdance-with/ythe approved TEM method:.,..;. Pii.;' This laboratory is-'in’‘-cdmplianceLwitlh':t'he; .quality '.specified forithe^ method:

Analyzed by: Report Reviewed by:

■p,;; Roman Peysakhov Michael’ A. Gorycki, Ph.D. ’'vf'' v'.: ‘ ■■•'•'i.vV.";3?v.c"’c. J,j'pir'ectpr-/pf, E'lectron Microscopy..-:

!

CONFIDENTIAL, CITY_21MC100_003390280 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000253072

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000253072Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos TEM analysis, PS 234M, Oct 2001

NYC-WTC_000373428

TEM-based asbestos analysis at PS 234M, project site noted; includes transmission electron microscopy and SAED/EDS methods.

Similar indexed content

Compare copies and versions →