WTC studies: sampling and exposure protocol

Machine-extracted title · confidence 32%

Proposed sampling and exposure studies for WTC-related materials.

NYC-WTC_000251032
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z Z WTC Indoor Air/Environments Monitoring - Sampling and Analytical Procedures For Background and Pilot Clean up Studies o co Analytical Description Analytical Method Proposed '2 o o Media Sampling Points Parameters Sampling Method Proposed

This is a micro va : - ling method. Three collocated samples will ■D c CT

ro Asbestos ASTM D 5755-95 ASTM D 5755-95 o' tn Settled Oust Carpets, fabric furniture or tc fected from each location. ■D o Porous Soft drapery in areas of activity O 3. tfO surfaces (living rooms, family rooms) This is a micro va... aing method. Three collocated samples will ro Lead ASTM E 1973-99 SW-846 601 OB 91 \ iiected from each location. O Asbestos

Lead ASTM D 6480-99

HUD Appendix 13.1 I Wipe Samples

Wipe Samples ASTM D 6480-99 (wipe)

SW-846 601 OB o o c 3 CD

Horizontal surfaces of Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 Settled Dust tables or counters and bare Non-porous PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C floors, ceilings and walls in Hard areas of activity (living Total Dust HUD Appendix 13.1" Wipe Sample collected at one location per unit. No Formal Method (NIOSH 7500 Modified) surfaces rooms, family rooms) Silica, calcite, NIOSH 7500 (XRD) HUD Appendix 13.1” Wipe Samples. All parameters will be collected on one wipe. gypsum MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300

Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA Asbestos NIOSH 7400 wkgroup detection limit method.

Lead Air pump operated at lOL/min for 8 hours to achieve the COPC NIOSH 7300 SW-846 6010B wkgroup detection limit SW-846 8270 (Analytical mathod with be Air pump operated at 2L7min for 8 hours. Pilot Clean-up study only PAHs NIOSH 5515 modified to achieve the COPC wkgroup detection for worst case scenarios. Areas of known activity limit Indoor Air (living rooms, family rooms) Air pump operated at 25L/min for 35 hours. This modification is not Dioxins TO-9 (Modified for indoor air) a proven method. To be conducted during the Pilot Clean-up study SW-846 8290 only for worst case scenarios. Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC NIOSH 7500 NIOSH 7500 (XRD) gypsum ________________ wkgroup detection limits________________

MMVF NIOSH 7400 Assumed that it behaves the same as asbestos, samples will be EMSL MSD.0300 combined with the asbestos sampling. Bulk samples will be collected from HVAC or AC window type unit Asbestos Bulk Sample PLM NYS 198.1 followed by filters, shaken into a plastic bag and transferred into the sample TEM NYS 198.4 container. Lead Bulk Sample (If the volume required is not attainable for all analysis, the sample SW-846 601 OB HVAC systems and AC ____________ will be analyzed for asbestos only. units (collection of bulk dust PAHs (If the volume required is not attainable tor all analysis, the sample Bulk Sample SW-846 8270 Bulk Dust sample from the unit air will be analyzed for asbestos only. filters). Background (If the volume required is not attainable for all analysis, the sample Dioxins Bulk Sample SW-846 8290 study only. ____________ will be analyzed for asbestos only. Silica, calcite, (If the volume required is not attainable for all analysis, the sample Bulk Sample NIOSH 7500 (XRD) gypsum will be analyzed for asbestos only. (If the volume required is not attainable for all analysis, the sample MMVF Bulk Sample PLM NYS 198.1/EMSL MSD.0300 will be analyzed for asbestos only.

NOTE: ** Wipe samples for silica, calcite and gypsum will be collected using Ihe HUD Appendix 13.1 method since no standardized method is available.

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251032Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348854

Proposed parameters and study design for WTC environmental sampling.

Similar indexed content

WTC sampling plan and procedures

NYC-WTC_000277652

Plan describing micro vacuuming sampling method and target materials (asbestos, lead, etc.).

Similar indexed content

Compare copies and versions →