Under the EPA NESHAP, 1% asbestos is not considered a safe level

1% only applies when defining the asbestos-containing building material itself

Region 2 Counsel agrees that 1% is not related to health risks

Region 2 Counsel states that 1% is only the detection limit of a crude method, PLM, that lacks sensitivity to test for lower levels

Region 2 Counsel, however, fails to state that EPA policy requires a more sensitive method, TEM, for settled dusts and other solids

In guidance under the Clean Air Act asbestos NESHAP, the EPA clearly states that the 1% level is only to be used to determine whether a building material itself contains asbestos, and that 1% is not a safe level, or a “standard.” Under the NESHAP, any dusts or contamination resulting from the use of building materials containing asbestos, which are called emissions, are regulated at much, much lower concentrations of asbestos in the dusts themselves.

In April 1973, the US Environmental Protection Agency (EPA) issued the National Emission Standards for Hazardous Air Pollutants (NESHAP) for asbestos (38 FR 8820). The NESHAP regulation governs the removal, demolition and disposal of asbestos containing bulk waste. An asbestos-containing product, as stated by the regulation was defined for the first time to be a product with greater than 1% asbestos, by weight. The intent of the 1 % limit was:

... to ban the use of materials which contain significant quantities of asbestos, but to allow the use of materials which would (1) contain trace amounts of asbestos which occur in numerous natural substances, and (2) include very small quantities of asbestos (less than 1 percent) added to enhance the material’s effectiveness. (38 FR 8821).

It most be clearly understood that the EPA NESHAP definition of 1% by weight was not established to be a health-based standard. [emphasis added]

[US EPA (April 18, 1989) Interim Asbestos NESHAP Enforcement Guidance - “Friable asbestos” 1% by Area of Volume vs. 1% by Weight. Office of Enforcement and Compliance Monitoring EPA Publication No. EPA 560/5-88-001. Available online at: http://es.epa.gov/oeca/ore/aed/comp/ecomp/e6.html ]

Region 2 Counsel agrees that the 1% level is not a safety standard, contradicting the other Region 2 claims. He states that this level only relates to the detection limit of the method that Region 2 chose to use in Lower Manhattan, the crude PLM method.

Note that the 1% standard is not necessarily health- or risk-based, but rather keyed to the detection limits of the specified analytical method.

[Mugdan, Walter E. (January 25, 2002) Environmental law issues raised by terrorist events. Speech before the NY Bar Association, NYC. Walter Mugdan is Regional Counsel for EPA Region 2.

-26-

CITY_21MC100_013381575

NYC-WTC_000250755

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250755Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →