EPA memo on air and dust asbestos testing, Mar 2002

Machine-extracted title · confidence 50%

EPA memo documenting issues with asbestos testing standards post-WTC collapse.

NYC-WTC_000250730–000250772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

If asbestos were present at Region 2's detection limits, levels would be higher than ERA'S 10 risk level

- A sensitive laboratory method is like looking at something with a microscope, or even an electron microscope

A cruder or less sensitive method is like looking for something with a hand-held magnifying glass.

A low detection limit is the same thing as high sensitivity. A much lower amount can be detected, like a microscopic grain of sand. The microscopic grain of sand is the "detection limit."

A high detection limit means low sensitivity. The detection limit would be larger, like only being able to detect a piece of gravel. The piece of gravel would be the "high detection limit."

The detection limits of the Region 2 air tests are too high, meaning that the tests did not have enough sensitivity to find asbestos at the levels that could harm people.

It is true that Region 2 was able to detect, asbestos at levels lower than 70 s/mm^ the AHERA test level. Many of Region 2's tests had no detectable asbestos at all. However, they were still not sensitive enough, and there are many ways of making the tests more sensitive.

The sensitivities, or detection limits, for the air tests Region 2 performed after the WTC collapse were only 0.0043 to 0.0096 structures per milliliter (s/mL), for all fibers and bundles. This corresponds to 0. 0011 to 0.0043 f/mL (PC'M). This assumes that either 25% or 50% of the fibers are PCM-equivalent, a conservative estimate, explained in an earlier section.

If asbestos were present at the detection limits or slightly below it, it would correspond to excessive cancer risks from nearly 3 per 10,000 up to 1 per 1000. See the following table.

CANCER RISKS AT REGION 2 DETECTION LIMITS

Cancer risk level Air concentration for “PCM-equivalent" fibers

1 per million 0.000004 f/mL (PCM) EPA’s Integrated Risk Information System

2.75 cancers per 0.0011 f/mL (PCM) estimated 25% PCM-equivalents for 10,000 lowest detection limit for Region 2 tests

1 cancer per 1000 0.0043 f/mL (PCM) estimated 50% PCM-equivalents for highest detection limit for Region 2 tests

- 17-

CITY_21MC100_013381566

NYC-WTC_000250746

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250746Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →