0.0128 24 3 0 9/23

0.0095 17.78 1 1 9/25 a

0.019 35.56 2 2

0.033 62.22 8 1

0.0074 17.78 1 1

0.0095 17.78 1 1 9/25

0.0190 35.56 4 3

0.0476 89.89 7 3

0.0143 26.67 2 1 9/29 a

0.0095 17.78 2 3 0.038 71.11 6 2 10/2

0.045 88.88 8 4

0.0143 26.67 2 1

Source: EPA air monitoring laboratory sheets. Made available in response to a Freedom of Information Act request from the New York Environmental Law and Justice Project. Posted at www.NYenviroLAW.orq Note that EPA only posted incomplete data on its web site, giving only asbestos concentrations expressed as structures per square millimeter, which is not helpful for scientists attempting to quantify risks.

70 s/mm^ - AHERA is higher than levels found at the Libby Superfund site

The 70 s/mm^ AHERA TEM clearance level is higher than the air levels found inside homes at the Libby, Montana Superfund site, the air levels that caused Libby to become a Superfund site.

The following table gives the air levels inside residences that resulted in the designation of Libby as a Superfund site. Because most of the inside air samples had non-detectable asbestos, it was necessary to estimate the detection limit of the tests performed at Libby. This estimate was from 0..0001 to 0.0003 f/mL (PCM).

The average level of asbestos inside residences in Libby is 0.0024 f/mL (PCM).

The AHERA 70 s/mm* level is equivalent to 0.0095 to 0.019 f/mL (PCM). (See preceding section.)

The AHERA 70 s/mm^ level is 4 to 8 times higher than the air inside residences at Libby.

- 15 -

CITY_21MC100_013381564

NYC-WTC_000250744

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250744Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →