AIR CONCENTRATION OF ASBESTOS CANCER RISK LEVEL, LIFETIME "PCM equivalent” fraction, fibers over 5 micrometers long number of cancers risk level

concentration fibers per expressed as exponent milliliter

0.000004 f/mL 4E-6f/mL 1 in 1,000,000 10'® (= E-6) 0.00004 f/mL 4E-5f/mL 1 in 100,000 10'® (= E-5) 0.0004 f/mL 4E-4f/mL 1 in 10,000 10“* (= E-4) Source: U.S. EPA (August, 2001) Integrated Risk Management Information System (IRIS) Summary for Asbestos, posted at http://www.epa.gov/iris/subst/0371.htm

Explanation of "PCM equivalent" asbestos fibers

The “PCM fraction” or “PCM equivalents” are those asbestos fibers! at least 5 micrometers (|im) long, with a width greater than 0.25 (im, and an aspect ratio greater than or equal to 3 to 1. These are the fibers that are small enough to be inhaled deeply into the lungs (“respirable size”), but also large enough to be retained by the lungs. It is believed that fibers shorter than 5 p,m can be engulfed by m:acrophages and carried out of the lungs.

EPA policy currently uses this “PCM-equivalent” theory, which means that asbestos fibers smaller than 5 (im in length are eliminated from the risk assessment, since they are believed not to contribute to cancer. Not all scientist agree with this theory, that the smallest of the small asbestos fibers are harmless.

Because the established EPA risk level is expressed in PCM equivalents, and because other asbestos in air data is typically expressed as PCM equivalents, it is useful to convert units from “total asbestos fibers” to “PCM equivalent fibers.” This makes comparisons of data easier.

70 s/mrn’ - AHERA is 2375 fo 4750 times higher than EPA's 10 risk level

The table below compares the AHERA 70 structures per square millimeter (70 s/mm^) level with the EPA one-in-a-million risk level (10'*^ risk level; ten to the minus six risk level).

Since the EPA one-in-a-million cancer risk level for asbestos is 0.000004 fibers per milliliter (PCM), the AHERA level is 2375 to 4750 times higher than the EPA cancer risk level. In other words, the 70 s/mm^ level would lead to 2.4 to 4.8 excess cancers per one thousand. This is unacceptable.

- 13-

CITY_21MC100_013381562

NYC-WTC_000250742

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250742Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →