NYC 9/11 Public Portal Document
[■^ resid^tial plan octi 8.wpd Page 28 ]
Attacluncnt 1
FINAL (October 11.2001) ATSDR, CrX?. EPA. OSHA Envirujunentul Assessment Woitgioup Asbestos Actifwj Levels for Wojld Trade Center Response
Action Level & Analysis Metliod General Public/Recononendations' Si^porting Infojmation- Comments
NYC Dack-ground’ PCM/PCMe* f/cc • No restriction on access to any area. AHERA standards (40 CFR • Remediation goal is to acliieve background levels.
(see iwtiuMo 2 luid 3) 761); ATSPR TosicdogiGd ’ Al (ERA guidance inrscluxils retjiiiiea tluil when schoob me !vin«y|»ate»l for
I’jotile li't AsU-slos; OSILA usivsios. the iiKkHM' iiir levels ofaslKSlos hlumld Iw siiiuliU' to tucul outdow air
29 CFR 1926.1101 levels.
• Lowest attainable Ciuicer risk
NYC Background to 0.01 Pcc PCNVPCWe’ ’ No restriction on access Io streets and public/ Al lERA stjuidards (40 CFR • No significant ciincer risk for sliort-lenn occupancy for residential and school
coiTunerdal building; continue to monitor 763); ATSDR Toxicological buildings.
• Evaluate to determine if long-tenn access is acceptable; Profile for Asbestos; IRIS; • AHERA guidance for schools requires that when sclioots are remediated for
evaluate trends over months. OSHA 29 CFR 1926.1101 aslvsios. the indoor ai r levels of asbestos sliould be similar to local outdoor air
■ Identify source levels
■ Take action, as practica!, to reduce levels to background
70 stmctuics'nan- TEM • If < dmn 70 s/iiun\ no restrictions on access to buildings Al lERA stiuidards (40 CFR • AHERA standards ajjply only to schools, and by NYC ordinance Io buildings. I
• If > 70 s/mm*. resample to confirm and analyze field blanks; 763) • Method sensitivity aid counting rules sliould follow Appendix A (Table 1} in
take action to idaitify source and reduce levels Io < 70 s'liuif NYC Clearance standard for AHERA 40 CFR 763; Method sensitivity based on H grids analyzed and air
Iwiil dings sample volume and must be mainiaitierl at 0.005 I7cc.
0.01 -0.1 f/cc PCM/PCMe’ • Continue to monitor, consider the need for additional Lowest limit sei at 1/10 • Leng-term exposures may increase cancer risk in the general public.
sampling sites. PEL/REL/TLV; AHERA • Unlike workers the general population, includes children and sensitive persons. J
• If air levels are consistenfly between 0.01 to 0.1 (Zee. standards (40 CFR 763); doesnot receive exposure moniioring and does not pardcipate in annual health
evaluate the need for advisories, the need to limit ATSDR To.\icological Profile screening
access and (he need for dust siqifxession.. for Asliestos; IRIS;
OSHA 29Cn< 1526.1101;
>0.1 f/cc PCM/PCMe’ • Evaluate ilic neexi Io restrict general public access. Unacceptable cancer risk General public sliould not be exposed to levels suspected of adverse health effects
• Continue to monitor, considertlie need for additional following long-term exposure; upon long-tenn exposure.
sampling ates.. AHERA standards (40 CFR
n 763). ATSDR To.xicological
LO
Profile for Asbestos; IRIS;
OSHA 29 CFR 1926.1101 I
n
o 28
co
o
NYC-WTC_000250572