NYC-WTC_000338505
First-draft explanation of TEM and PCM asbestos identification methods.
5 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗Overview of TEM and PCM methods for asbestos identification and levels of concern.
NYC-WTC_000250491
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
FIHST DRAFT
Testing Methodologies For Asbestos
Air: l.i' \ is currently collecting air samples for asbestos and analyzing them via electron microscopy (TEM). They are using the EPA AHERA TEM guidance (see below)
Transn'ission Electron Microscopy (TEM)-
o TEM can distinguish between asbestos from non-asbestos material. o TEM can see very thin fibers that are not seen by PCM (see below). o TEM is considered to be the definitive state-of-the-art method for identifying asbestos fibers. o For the WTC response, The EPA AHERA TEM methodology established in the l980’s is being used as a level of concern. The AHERA standard of 70 structures per square millimeter of filter paper is considered very protective of health. Leveks above the 70 structures standard do not imply an immediate health threat.
PCM Phase Contrast Microscopy-
o PCM identifies fibers but cannot distinguish asbestos from non-asbestos fibers. Although asbestos fibers less than Sum in length can be identified, only fibers greater than Sum in length are counted. According to ATSDR, CDC, EPA, and NIOSH, fibers less than Sum in length are toxicologically insignificant. Asbestos fibers greater than S urn in length, and especially those longer than 10 um, are associated with health effects.
o PCM cannot identify fibers with diameters less than 0.25 um. Therefore, in some cases, this method can “underestimate” the number of fibers by missing the thinner fibers The more sensitive electron microscope (TEM) is required to see these thinner fibers.
o PCM in some cases can also “overestimate” the number of fibers because this nethod mav count non-asbestos fibers.
o because PCM may overestimate or underestimate asbestos air concentrations, the :nore definitive TEM' method is preferred.
0 Many of the early worker and animal exposure studies used the PCM method to determine asbestos exposure levels, and current risk assessment methodologies still use the PCM counting methods. Therefore, the counting rules established by PCM are used for TEM analysis to acquire PCM equivalents (PCMe).
CITY_21MC100_013489305 NYC-WTC_000250491
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000338505
First-draft explanation of TEM and PCM asbestos identification methods.
5 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318598
Draft guidance document on TEM/PCM analysis and air testing for asbestos.
5 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279330
First draft outlining TEM/PCM methods for asbestos identification and analysis.
5 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338506
Comparison of PCM and TEM methodologies for asbestos exposure assessment.
5 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338508
Overview of asbestos monitoring results and TEM/PCM interpretation for ERA data.
5 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275413
Alternate page summary of asbestos air testing at 130 Water Street.
2 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275410
Summary of asbestos air testing results for 130 Water Street, detailing locations and analyses.
2 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242873
Air and dust samples collected at 130 Water Street; results assess asbestos fiber levels.
2 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208370
Report detailing air and dust sampling procedures and results for asbestos at a residential building on Water Street following the attacks.
2 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302884
AHERA TEM clearance criteria and measurement details for school asbestos abatement.
3 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
1 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208744
Lab report detailing industrial hygiene asbestos air sample analysis methods including PCM and TEM for worker exposure assessment.
1 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000338505
First-draft explanation of TEM and PCM asbestos identification methods.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318598
Draft guidance document on TEM/PCM analysis and air testing for asbestos.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320047
Draft guidance comparing TEM and PCM microscopy for asbestos identification.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279330
First draft outlining TEM/PCM methods for asbestos identification and analysis.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320382
Background on air sampling methods (PCM and TEM) used for asbestos assessment near WTC.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338506
Comparison of PCM and TEM methodologies for asbestos exposure assessment.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000338505
First-draft explanation of TEM and PCM asbestos identification methods.
Similar indexed content
NYC-WTC_000318598
Draft guidance document on TEM/PCM analysis and air testing for asbestos.
Similar indexed content
First draft outlining TEM/PCM methods for asbestos identification and analysis.
Similar indexed content
NYC-WTC_000338506
Comparison of PCM and TEM methodologies for asbestos exposure assessment.
Similar indexed content
NYC-WTC_000338508
Overview of asbestos monitoring results and TEM/PCM interpretation for ERA data.
Similar indexed content