NYC 9/11 Public Portal Document Mar-lS-02 l0:23am Fron- T-326 P.003 F-B56

Purpose of Blanks

The purpose of obtaining blanks is not to identify if the sample results are statistically different from the blanks. Blanks were utilized to: 1) assess the ability of the sampling and analysis methodology to accurately estimate the amount of dust in the air at the sampled location, and 2) to validate that there was no sample contamination problem - from field collection through sample analysis. For this sampling effort the variation in the blanks represent the variation in the measured sample concentrations that may be due to the methodologies and not due to the level of dust at the sampling locations.

Evaluation of the weight gain (or weight loss, but generically weTl just call it ‘weight gain’) of the blanks provides basic information useful for understanding three important concepts associated with the measured concentration of dust in the sample locations. First sample gathering/analysis errors identified during the evaluation of the blanks could also have occurred during the sample gathering/analysis of the measured samples. It maybe more difficult to identify those errors solely by observing the sample concentrations due to the variability in the sample filter weight gain from the dust in the sampled air. Evaluation of the blanks can help identify potential types of errors that could also affect the measured samples. Second the blanks demonstrate the basic variability inherent in the sample gathering/analysis methodology. Ideally the blanks are treated the same way the sample filters are, except for being exposed to the sampled air. Variability in the blank results due to the method will also be present in the results of the sample filters. Third evaluation of the variability in the blanks can be used to identify the minimum weight gain or measured concentration that the sample filters must exceed in order for us to feel confident that the measured concentration is actually different than that due to the variability due to the sampling/analysis method.

Figures 13 through 24 in attachment 1 show the measured sample concentration with the associated calculated blank concentrations for each measurement location (outdoor, common area, and residential units) for each particle size. In some cases the available data was limited (an extremely low value of a PMIO blank was not included) in order to better show the variation in the remaining data. Notice that the measured sample concentrations tend to overlay the calculated blank concentrations. This is likely to be the source of the significant statistical difference. In order to accurately estimate the concentration of dust at the sampling location, it is necessary to first be sure that the weight gain of the sample filter is due to dust deposition during the sampling event, and not due to the variation between the final and initial weight that occurs as a part of the sample gathering/analysis procedure.

Evaluation of the Weight Gain of the Blanks Figures 2a through 2d in atuchment 1 show the frequency distribution of the weight gain (final weight - initial weight) for the blanks for each particle size. As discussed in that text, the vertical lines are set at +/- .03 mg and represent the limit of detection (LOD) expected for this general sample gatherin^analysis method. This means that the expected final weight of each blank is +/- .03 mg different than the blank’s initial weight. This LOD is described in the analysis method (reference) and identifies the variability that is expected in the blanks when the sample gathering/analysis procedures are properly performed. For PMIO and PM4 a large fraction of the blanks had a positive or negative

NYC-WTC_000250382

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250382Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →