Frequency Distribution of Weight Change in Seiected Bianks

18

16

14 -

12 PM100 B PM10 S' 10 I £ 8 X PM4 PM2.5 -------- k — Lower LOD ------- — —Upper LOD 6

■ ■ 2 ----- --------------------- B B n IB B 0 -I— -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5

Weight Change [mg]

The dashed vertical lines show the upper and lower limits of detection expected for this method (+/- 0.03 mg). The distance between limits of detection represents the maximum weight gain expected for the blanks if the entire sampling procedure was followed as required by standard sampling methodologies. Ali! of the size fractions had at least two blanks outside the limit of detection boundaries. (The two out of range blanks for PMIOO are not shown on the graph because they are also beyond the boundaries of the graph). Approximately 6% of the PMIOO, 70% of the PM 10, 57% of the PM4, and 8% of the PM2.5 blanks had weight changes greater than the limit of detection.

In general, blanks are used (1) to assess the ability of the sampling and laboratory analysis methodology to accurately estimate the concentration of particulate matter in the air at the sampled location and (2) to validate that there is no filter contamination problem from the time the blanks are initially weighed in the laboratory until the time the blanks are weighed in the laboratory after sampling. Errors could occur at any step in the process.

The large weight change of the blanks indicates eirors in either the laboratory weighing process or the air sampling process. The graph illustrates that the results of the airborne particulate matter sampling cannot be used to reliably estimate the actual concentration of any of the particulate matter size fractions; therefore, the entire data set was rejected from further consideration.

92

CITY_21MC100_011109649

NYC-WTC_000276925

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276925Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →