Paradigm lab hydrocarbons results, IAQ-B-2A-001

Machine-extracted title · confidence 68%

GC-MS hydrocarbons results for IAQ-B-2A-001, World Trade Center Response samples.

NYC-WTC_000250277
Page image
Scanned page image, NYC-WTC_000250277
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Maa 06 02 03:30p

PARADIGM ANALYTICAL LABORATORIES, INC.

Results for Polynulcear Aromatic Hydrocarbons by GCMS Client Sample ID: IAQ-B-2A-001 Date Collected: 4/30/2002 Client Project ID: World Trade Center Response Date Received: 5/1/2002 Lab Sample ID: 42737 Date Analyzed: 5/3/2002 Lab Project ID; G493-63 Analyzed By: MRC Matrix: Dust Dilution: 10

Quantitation Result Compound Limit (ug/KG) (ug/KG) Acenaphthene 1200 3800 Acenaphthylene 1200 BQL Anthracene 1200 10000 Benzo[a]anthracene 1200 18000 Benzo[e]pyrene 1200 11000 Benzo[a]pyrene 1200 17000 Ben2o(b]fluoranlhene 1200 20000 Benzo[g,h.i]perylene 1200 12000 Benzo[k]nuoranthene .... 1200 7600 Biphenyl 1200 BQL Carbazole 1200 6500 Chrysene 1200 18000 Dibenzo[a.h]anthracene 1200 3400 Dibenzofuran 1200 2800 2,6-Dimethylnaphthalene 1200 BQL Fluoranthene 1200 42000 Fluorene 1200 4900 lndeno(1,2,3-c,d)pyrene 1200 13000 1-Methylnaphthalene 1200 BQL 2-Methylnaphthalene 1200 BQL Naphthalene 1200 1900 Phenanthrene 1200 36000 Pyrene 1200 33000 r?r- Spike Spike Percent Surrogate Spike Recoveries Added Result Recovered 2-Fluorobiphenyl 10 0.8 83 4-Terphenyl-d14 10 1.0 103

Comments; Results are reported on a wet weight basis.

Flags; NA = Not applicable, surrogates diluted out. BQL = Below Quantitation Limit.

Reviewed By;

N.C. Certification Certification #99029 CITY_21MC100_013489136 NYC-WTC_000250277

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250277Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →