AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. of Economics and Finance Page 5 of 8

sufficient amount of dust for bulk sampling and/or analysis will be noted as Not Sufficient Amount of Material for Testing (NSAMT)

In the event that any of PLM analysis detect more than 1% by weight of fiberglass, BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

LEAD SURFACE DUST

• First floor lobby outside auditorium - one sample.

• Cafeteria - one sample.

• Auditorium - one sample.

• Two random classrooms - one sample from each classroom

• Third floor Hallway - one sample

• Fifth floor Hallway - one sample

• Seventh floor Hallway - one sample

• Ninth floor Hallway - one sample

All dust wipe samples taken shall be analyzed in accordance with EPA7082 method via Flame Atomic Absorption (FAA).

Dust wipe results shall be considered satisfactory when the levels obtained are below the EPA new levels for clearing a work area for re-occupancy after an EPA defined lead abatement is performed, as specified in 40 CFR §745.227(e)(8)(viii).

Floors: 40 micrograms of lead per square foot Window Sills: 250 micrograms of lead per square foot

Dust wipe results shall be considered unsatisfactory when the levels obtained are greater than the EPA new levels for clearing a work area for re-occupancy after an EPA defined lead abatement is performed, as specified in 40 CFR §745.227(e)(8)(viii).

Floors: 40 micrograms of lead per square foot Window Silis; 250 micrograms of lead per square foot

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant within 24 hours.

In the event that unsatisfactory results are obtained, the following actions are to be implemented:

1. Perform general dust clean up of all areas/classrooms with unsatisfactory results.

CONFIDENTIAL INSURANCE INFORMATION, CITY_2 IMCl U U_0 Li 2 2 U 8 2 3 U SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 NYC-WTC_000250247

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250247Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000385892

Ambient air protocol for H.S. Economics and Finance following WTC cleanup.

Similar indexed content

NYC-WTC_000385905

Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.

Similar indexed content

Compare copies and versions →