Lab report on asbestos risk, PS/IS89, Jul 2003

Machine-extracted title · confidence 28%

Notes from insurance company regarding asbestos exposure assessment and initial testing results at PS/IS89.

NYC-WTC_000250227
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Turchetto Gerald From: Turchetto Gerald Sent; Wednesday, July 16, 2003 2:50 PM To: Orlan Bernard; Lempert Alex Cc: Hemida Mohamed; Rosillo Juanita; Sanders Ira Subject: PRIVILEGED AND CONFIDENTAL: PS/IS89

Bernie, Alex, Mohamed, Below is a passage from the most recent letter from the insurance company that covers PS/IS89 (all errors occur in the letter itself), regarding why the company believes that the interior of the building did not require a full-blown asbestos contamination level clean-up: 'We have copies of reports for the initial testing conducted by ATC which I will outline as follows: 1) Lead dust wipe sampling report dated January 2002. The lead dust samples were taken on 1/11/02 and the results were that all samples collected contained lead beiow the floor and windowsill surface clearance guidelines set at 40ug/sq ft and 250 ug/sq. ft. respectively 2) Eleven metals were analyzed as follows: Aluminum, Cadmium, Chromium Cobalt, Copper, Iron, Magnesium, Manganese, Molybdenum, Nickel & Zinc where the samples were taken on 12/22/01. The conclusion by ATC was that detectible levels often metals were found in the samples however ATC does not believe that cleaning of the surface in the school is necessary. 3) The Air Sampling of Dioxins collected on 12/15/01 for PCDD's, & PCDF's showed that indoor concentrations were below the EPA screening level of 0.16 ng/sq. m 4) Report on TEM Analysis dated 2/2/02 does not detect any asbestos types. 5) Air sampling Of mercury completed on 12/18/01 detected no mercury greater than that detected in the blank. 6) The settled dust sampling of asbestos report dated 11/12/01 confirms that of the 68 samples taken using PLM one sample found on settled dust on the soil outside the building contains asbestos greater than 1%. All other contained either none or less than 1% asbestos. 7) Real Time Air Monitoring repot dated 12/19/01 found that observations of the specified parameters they conclude that the indoor air quality was acceptable 8) Report on TEM Analysis dated November 6, 2001 shows of the 25 samples in the report, four samples came back positive for asbestos types. Sample 6-Amosite at a level of .0045, Sample 8-Chrysotile at a level of .0045, Sample 11-Chrysotile at a level of .0045 & Sample 25- Chrystotile at a level of .0091. "While I may not disagree with yours and ATC's assertions that asbestos fibers have been detected, the detection rate was . 0091 or less (as outlined in their report's dated November 6, 2001 and November 11, 2001 which I believe should have set the cleaning protocols) was detected. As you know, the level of. 0091 is less than the industry standard of .01 to have an asbestos condition that needs to be treated as such. "With all the supporting reports above we still maintain that that cost to wet wipe the entire building only, on a non asbestos cleaning basis, is the $63,354 previously offered."

Do you agree with their findings and conclusions, i.e., that a full-blown "spacesuit" cleaning of the building was not warranted on a strictly technical (standards-referenced) basis?

1

NYC-WTC_000250227

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250227Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →