ATC report, wipe dioxin samples, PS 150M

Machine-extracted title · confidence 48%

ATC Associates July 2002 wipe sample report for dioxins at PS 150M.

NYC-WTC_000250212–000250213
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan July 1,2002 Wipe Samples for Dioxin Page 2 P. S. 150 (Manhattan) ATC Project No. 15-19125-0289 » The sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. A copy of the laboratory analysis report is attached. Tlie results of the samples are shown in the following table:

DIOXIN WIPE SAMPLE RESULT (2,3, 7, 8 TCDD EQUIVALENTS) - Nanograms per square meter (ng/m^) ________________________ May 13,2002________________________

1st Floor Main Entrance- Lobby/DXl 0.00025 Blank/DX2 0.000024

Tile New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^). The dioxin concentration in these samples is below the NYSDOH guideline.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in this sample was deposited. Dioxin samples were not collected from this location prior to December 13, 2001.

It is our pleasure to provide these indoor environmental services to thp NYC Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212.

Sincerely, ATC Associates, Inc. Reviewed By:

Yiannis Efstathfou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC1OO_OO576O2O9 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000250213

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250213Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000224772

Letter report from ATC Associates providing results of wipe samples for dioxins and dibenzofurans collected at P.S. 150M in May 2002.

Similar indexed content

Compare copies and versions →