Dioxin wipe sample results, PS ISOM, June 2002

Machine-extracted title · confidence 95%

ATC Associates report on polychlorinated dibenzo-p-dioxins and dibenzofurans collected at PS ISOM in May 2002.

NYC-WTC_000178044–000178045
Page image
Scanned page image, NYC-WTC_000178045
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan June 13, 2002 Wipe Samples for Dioxin Page 2 P. S. 150 (Manhattan) ATC Project No. 15-19125-0289

Tlie sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. A copy of the laboratory analysis report is attached. The results of the samples are shown in the following table:

DIOXIN WIPE SAMPLE RESULT (2,3,7, 8 TCDD EQUIVALENTS) - Nanograms per square meter (ng/m^) _________________________ May 6, 2002_________________________

ist Floor Main Entrance- Lobby/DXl 0.00031 Blank/DX2 0.00

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^), The dioxin concentration in this sample is below the NYSDOH guideline.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in this sample was deposited. Dioxin samples were not collected from this location prior to December 13, 2001.

It is our pleasure to provide these indoor environmental services to th? NYC Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212.

Sincerely, ATC Associates, Inc. Reviewed By:

/ u James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_005760198 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000178045

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000178045Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →