NYC-WTC_000250132
Determination of PCDD/PCDF levels for ATC client at 104 East 25th Street.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Determination of PCDD/PCDF levels for ATC at NYC site, report for client.
NYC-WTC_000250102–000250122OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ^ace Analytical" Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444
PROJECT: PCDD/PCDF ANALYSES DATE: March 5, 2002
PAGE: 6 REPORT NO: 02-1054208
Quality Control for PCDD/PCDF Analyses
The performance of the sample processing steps and the instrumentation are monitored on a routine basis. The procedures and criteria are summarized below.
One method blank and one laboratory spike sample are typically prepared with each ten samples of any given matrix. Recoveries of the native PCDD/PCDF analytes in the laboratory spike samples generally range from 70 to 130%. Recoveries of selected analytes outside this range do not invalidate the data but provide information, which is used by the laboratory to monitor recovery trends and to assure optimization of the method.
Internal standards are spiked into each sample prior to extraction in order to monitor the level of recovery, which is achieved for each individual sample. Acceptable recoveries range from 40 to 135 percent for the internal standards unless a deviation is due to variation in instrument response as a result of analytical interferences.
The resolution of the mass spectrometer is verified prior to each analysis to be 10,000 or greater. Hardcopies of the reference peaks are printed at the beginning and end of each analysis day. The resolving power of the DB-5MS chromatographic column is checked daily using a standard solution containing 2,3,7,8-TCDD and the adjacent TCDD isomers. The DB-225 column resolution is checked daily using a standard solution containing 2,3,7,8-TCDF and the adjacent TCDF isomers. Acceptable performance is achieved when 2,3,7,8-TCDD or 2,3,7,8-TCDF is resolved from the adjacent isomers by a valley of 25% or less. The group times for the selected-ion-monitoring data acquisitions are aliso checked daily by analyzing the column performance mix which has been modified to contain the first and last eluting isomers of each congener class. In this way one is assured of collecting data representative of the total PCDD/PCDF content and that the 2,3,7,8- substituted isomers are suitably resolved.
Initial calibrations are generated by analyzing standard solutions (see Table 4) containing target native and labeled PCDD/PCDF compounds. Response factors are calculated and averaged for each compound. These averages are used for quantification and for comparison to the daily continuing calibration. The relative standard deviation for each native compound must be 20% or less (30% or less for the labeled compounds) as specified in Method 8290. A continuing calibration standard is analyzed at the beginning and end of each 12-hour shift on days when initial calibrations are not performed. The initial calibration is considered to be valid when the response factors from the continuing calibration analysis fall to within the ranges specified in Method 8290.
REPORT OF LARORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.
fnphrt CONFIDENTIAL, CITY_21MC100_005760076 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000250108
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000250132
Determination of PCDD/PCDF levels for ATC client at 104 East 25th Street.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375724
Laboratory results for project 19125-0289 with PGDD/PCDF determinations, 21 pages.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000399555
Laboratory determination report for PCDD/PCDF, ATC 19125-0279, 104 East 25th Street.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375748
Laboratory analysis report for ATC project, TEM/analysis, 21 pages.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400852
Pace Analytical lab report; project [name]; 19125-0246; 22 pages; general analysis.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226877
Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400694
Pace Analytical lab report; project 19125-0246, 23 pages.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272110
Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400723
PACE lab report; 30 pages, NELAC standards, project 19125-0246.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400775
Pace Analytical report with 23 pages; chemistry/NELAC standards; project ID partially visible.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000399532
Laboratory analysis report for PCDD/PCDF on ATC project 19125-0279, 104 East 25th Street.
9 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000300414
Report of PCDD/PCDF determinations for ATC project; laboratory details and client info on file.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326628
Analytical lab report for PCDDs & PCDFs; city file reference.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256565
PACE Analytical report/dossier with NYC project details and determinations.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400852
Pace Analytical lab report; project [name]; 19125-0246; 22 pages; general analysis.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348993
Determination of PCDD/PCDF levels for project: World Trade Center.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000250132
Determination of PCDD/PCDF levels for ATC client at 104 East 25th Street.
Similar indexed content
NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
Similar indexed content
Laboratory results for project 19125-0289 with PGDD/PCDF determinations, 21 pages.
Similar indexed content
NYC-WTC_000399555
Laboratory determination report for PCDD/PCDF, ATC 19125-0279, 104 East 25th Street.
Similar indexed content
Laboratory analysis report for ATC project, TEM/analysis, 21 pages.
Similar indexed content