NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Analytical results, ATC air PCBs, Dec 2001

Machine-extracted title · confidence 34%

ATC 12/8/01 PCB air analysis results, Dec 2001.

NYC-WTC_000249650–000249652
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Dec 19 01 02;5ap PSC Rnalytical Services 6109219EB7 P-3

INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING •EP/VNVLAP101262-0 •N/DOH/NELAC 10903 •NJ DEP 77020 • AIHA ACCREDITATION NO. 100439 • PA OEP 06-353 •Cl DPH PH-D238 •NCDENR599

ANALYTICAL SERVICES Analytical Results for ATC Associates WorkOrder: R0n20169 Client Reference: 19125-0246: PCBs in Air (12/8/01)

Analyte Concentration Limit of Test Date .Analyzed Detection Method /Analyst (ug) ; (mg/mO ; (ppm) (ug)

Client ID: PCB1 -ATC- i 20S-234M Lab ID: -01A Dale Sampled; 12/8/01 Matrix: Ten ax AirVol.(L): 120 Aroclor 1016 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1221 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1232 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1242 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1248 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1254 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1260 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF

Client ID; PCB2-ATC-1208-234M Lab ID; -02A Date Sampled: 12/8/01 Matrix: Tenax AirVol.(L): 120.S Arodor 1016 <0.5 <0.0041 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1221 <0.5 <0.0041 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1232 <0.5 <0.0041 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1242 <0.5 <0.0041 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1246 <0.5 <0.0041 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1254 <0.5 <0.0041 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1260 <0.5 <0.0041 0.5 POLYCHLORINATED 12/16/2001 GIF

Client ID: PCB3-ATC-1208-234M Lab ID: -03A Date Sampled: 12/8/01 Matrix: Tenax AirVol.(L): 120 Aroclor 1016 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1221 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1232 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1242 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1248 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1254 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1260 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF

Client ID: PCB4-ATC-120S-234M LablD: -04A Date Sampled; 12/8/01 Matrix: Tenax Air VoI.(L): 120 Aroclor 1016 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1221 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1232 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1242 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1248 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1254 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF Arodor 1260 <0.5 <0.0042 0.5 POLYCHLORINATED 12/16/2001 GIF

Page 1 of3

CONFIDENTIAL, CITY_21MC100_003445018 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249650

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249650Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

PCB air analysis results, NYC BOE, Dec 2001 · page 1

NYC-WTC_000223514

Analytical report from PSC Analytical Services detailing results for polychlorinated biphenyls in air samples collected at a New York City Board of Education site.

Similarity score 0.994 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

PCB air analysis results, NYC BOE, Dec 2001

NYC-WTC_000223514

Analytical report from PSC Analytical Services detailing results for polychlorinated biphenyls in air samples collected at a New York City Board of Education site.

Similar indexed content

Compare copies and versions →