Correspondence: Air sampling at P.S. 234M, 2001

Machine-extracted title · confidence 32%

ATC Associates letter re: PCB air sampling at PS 234M, Dec 2001.

NYC-WTC_000249645
Page image
Scanned page image, NYC-WTC_000249645
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th Street JAI New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353,8306 ASSOCIATES INC.

December 21, 2001

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Polychlorinated Biphenyls (PCBs) P.S. 234M ATC Project No. 15-19125-0279

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for polychlorinated biphenyls (PCBs) conducted on December 6 and 8, 2001, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., a consultant retained by the parents association.

On each day, ATC collected eight (8) samples for PCBs at specified locations. Samples were collected for ten (10) hours using 37 mm glass fiber filters and Florisil® tubes connected to battery-powered sampling pumps at a flow rate of 0.2 liters per minute. Pumps were calibrated before and after each sampling period. Four (4) samples were collected inside the building and four (4) were collected outdoors. One blank sample was also submitted on each day. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association- accredited laboratory in Reading, PA. Analysis was performed by NIOSH Method 5503. Each sample was analyzed for a panel of seven (7) PCB compounds. Copies of the analytical reports are attached.

The sampling locations were specified by the parents association consultant. They were as follows: Cafeteria, Room 118, 2"“^ floor hallway, Room 315, Outdoors by main entrance, Outdoors in front courtyard, Outdoors in back playground. Roof by the air intake.

No PCBs were found above the limit of detection in any of the samples.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, I:

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003445011 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249645

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249645Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →