NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax' 612- 607-6A44
/
I Client - ATC
Client's Sample ID ATC-1220-89M-DX4
Lab Sample ID 103233920
Filename F11228B_06
Injected By BAL
Total Amount Extracted 1 m2 Matrix wipe:
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/20/2001
ICAL Date 11/19/2001 Received 12/21/2001
CCai Filename(s) F11228B_01 & F11228B_16 Extracted 12/23/2001 •
Method Blank ID BLANK-1389 Analyzed 12/29/2001 01:30
Native Cone EWIPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0026 0.00200 J 2,3,7,8-TCDF-13C 2.00 58
3 Total TCDF
2,3,7,8-TCDD
0.0540
ND
0.00200
0.00200
2,3,7,8-TCDD-13C
1,2,3,7,8-PeCDF-13C
2,3,4,7,8-PeCDF-13C
2.00
.2.00
2.00
72
59
59
Total TCDD 0.0840 0.00200 1,2,3,7,8-PeCDD-13C 2.00 71
1,2,3,4,7,8-HxCDF-13C 2.00 73
tiS 1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 73
2,3,4,7,8-PeCDF ND 0.01000 2.3,4,6,7,8-HxCDF-13C 2.00 74
Total PeCDF 0.0220 0.01000 J 1,2,3,7,8,9-HxCDF-13C 2.00 71
1,2,3,4,7,8-HxCDD-13C 2.00 98
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 78
Total PeCDD 0.1000 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 72
1,2,3,4,7,8,9-HpCDF-13C 2.00 67
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 81
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 56
2,3,4,6,7,8-HxCDF ND 0.01000
"T 1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
it Total HxCDF 0.0200 0.01000 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 75
1,2,3,6,7,8-HxCDD ND 0.01000
ri 1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD 0.1600 0.01000
1,2,3,4,6,7,8-HpCDF 0.0210 0.01000 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.0013 ng/m2
Total HpCDF 0.0210 0.01000 J (Using ITE Factors)
1,2,3,4.6,7,8-HpCDD 0.0480 0.01000 J
Total HpCDD 0.0890 0.01000 J
J
OCDF 0.0230 0.02000 J
OCDD 0.3100 0.02000
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EM PC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
FleportNo.... 01-1052540
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003474161
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000249277
OCR can misread numbers and units. Confirm readings against the page image before using them.