NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, Stuyvesant H.G., Oct 2001

Machine-extracted title · confidence 32%

TEM asbestos fiber analysis at Stuyvesant High School site, identifying asbestos via TEM methods.

NYC-WTC_000248507
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board cf Education Approved N.Y. State SLAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Leng Island City, NY 11101 Report Date: 10/05/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: Z.HERA F.nal Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1937

Sample Identitication Analysis Parameters

Prcject/Sice: Stuyvesant H.G., 345 Chambers St., NY, NY TEM Sample No.; 5609 60061 Floors 1-10

Cate Received Grid Openings Analyzed; __ 4

Project Sample No.:.mVtU;U2irii Average Grid Opening:106;G 0 um

Air Volume: 1929 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diari., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective A.re£ ; 385 mm2 0.0044 s/c:

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single­ Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct Struct Struct/mrr.2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 c 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbest.os 0 0 Q 0 0 0.0 o.ooco N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.oooo N/A The estimsted uncertainty o: this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole AsbestOfS Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO34736O7

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248507

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248507Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244721

TEM asbestos analysis; exterior/interior of building, sample 5737, received 10/21/01.

Similar indexed content

Compare copies and versions →