Asbestos TEM analysis, Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 43%

TEM asbestos analysis for Stuyvesant High School, SAED/EDS methods.

NYC-WTC_000248490
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLA? Lab Code # 1187 Long Island City, NY 11101 Report Date: lO/05/Cl

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identificatren by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: ZiHERA F_nal Rule, IRA Federal Register (40 CER, Part 763), Vol, 52, No. 210, October 30, 1987

Sample Idemtification Analysis Parameters

Project/Site: Stuyvesant H..3., 345 Chambers St., NY, NY TEM Sample No.; 5609 60044 Floors 1-10 Date Received: 10/05/01 Grid Openings Analyzed;__ 4

Project Sample No.: SH3-l>10-10/5-37 Average Grid Opening; 106.00 um

Air Volume: 1953 liters Total Area Ar.alyzed: 0.0450 mm2

Filter Type: MCE 25 mm ciam.• Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm2 0.0046 s/oc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Sr.nole Matrix Total. Struct Filter Air Fibers: Bundles Clusters Struct. Struct > = 5 uin Struct/mm? Struct/cc nam/tnl

Chrysotile Asbesros C 0 0 0 0 0 0.0 0 . 0000 0

AmphiDole Asbestos 0 0 0 0 0 0 0 .0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0 .0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0 .0000 0 Non-Asbest.os 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 3 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by. Report Reviewed by.

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473590

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248490

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248490Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos TEM analysis, 5784, 10/28/01

NYC-WTC_000248341

TEM asbestos fiber analysis; New Stuyvesant HS; exterior/interior; SAED/EDS; received 10/22/01; analyzed 10/28/01.

Similar indexed content

Compare copies and versions →