NYC-WTC_000330206
TEM asbestos analysis with SAED/EDS for NYC project, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗TEM asbestos identification; SAED/EDS for Stuyvesant HS, Oct 2001.
NYC-WTC_000248475OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
A.TC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber IdenciticatLon joy Selected-Area Electron Diffraction (3AED) and Energy-Dispersive X-RAY Spectroscopy (EDS; Method: AiER?. Final Rule, £:PA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Ident-ficazion Analysis Parameters
Proj scc/Sit;e: Stuy-zesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5609 60026 Floors 1-10 Dace r.scer.ved: 10/05/01 Grid Openings Analysed;__ 4
Project Sample No. SNS- 1 >1 0- lQ/5-15 Average Grid Opening: 106.00 um
Air Volume: 1891 liters Total Area Analyzed: 0.0450 mm2
Filter Tyi:e: MCE 25 mm diam., Pore Size: 0,45 um .Analytical Sensitivity ; 2 2:2 s/mr[u Effective Area: 335 mm2 0.0045 3/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Glus’" prs Struct. Struct > = 5 um Struct/’mm2 Strucc/ci nqm/m3
Chrysotile Asbestos 1] 0 0 0 0 0 0.0 0 . ocoo 0
Amphibole Asbestos I? 0 0 0 0 0 0.0 0 . ocoo 0
Ambiguous (5 0 0 0 0 0 0.0 0 . OCOO 0
Total asbestos (includes amoiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/.A No Identification 0 0 0 0 0 0 0.0 0.0000 N/.A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty o: this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473573 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000248475
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000330206
TEM asbestos analysis with SAED/EDS for NYC project, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324119
Asbestos fiber analysis by TEM for MAT project, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200248
Laboratory report from ATC Environmental showing asbestos fiber analysis by TEM for air samples collected at the High School for Economics and Finance.
3 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411482
TEM asbestos analysis for 328 W. 14th St. site, Sept 28, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270930
TEM-based asbestos analysis for exterior/interior of New Stuyvesant H.S., Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248306
Asbestos TEM analysis with SAED/EDS for New Stuyvesant H.S., received 10/27/01.
6 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294141
TEM analysis parameters for Stuyvesant HS project (opening and air volume).
6 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248465
TEM analysis data for Stuyvesant High School, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270755
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
5 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330199
TEM asbestos analysis with SAED/EDS for NYC DOE project, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330162
TEM report with project/site details and sample identifiers.
5 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248492
TEM asbestos analysis for Stuyvesant High School; AHERA/ERA methods.
5 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000330206
TEM asbestos analysis with SAED/EDS for NYC project, Oct 2001.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324119
Asbestos fiber analysis by TEM for MAT project, Oct 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200248
Laboratory report from ATC Environmental showing asbestos fiber analysis by TEM for air samples collected at the High School for Economics and Finance.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411482
TEM asbestos analysis for 328 W. 14th St. site, Sept 28, 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248306
Asbestos TEM analysis with SAED/EDS for New Stuyvesant H.S., received 10/27/01.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294141
TEM analysis parameters for Stuyvesant HS project (opening and air volume).
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000330206
TEM asbestos analysis with SAED/EDS for NYC project, Oct 2001.
Similar indexed content
NYC-WTC_000324119
Asbestos fiber analysis by TEM for MAT project, Oct 2001.
Similar indexed content
NYC-WTC_000200248
Laboratory report from ATC Environmental showing asbestos fiber analysis by TEM for air samples collected at the High School for Economics and Finance.
Similar indexed content
NYC-WTC_000411482
TEM asbestos analysis for 328 W. 14th St. site, Sept 28, 2001.
Similar indexed content
TEM-based asbestos analysis for exterior/interior of New Stuyvesant H.S., Oct 2001.
Similar indexed content