Asbestos TEM analysis, Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 40%

TEM asbestos analysis for Stuyvesant High School, Oct 2001.

NYC-WTC_000248470
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) Wit.h Fiber Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy ;EDSi Method; AiERA Final Rule, EPA Federal Register (40 CFR, Part 163), Vol, 52, No. 213, October 30, 1987

Sample Ident-fication Analysis Paramecers

Project/SiI:e Stu-/vgsar.t H.£., 345 Chambers St., NY, NY TEM Sample No.: 5609 60C21 Floors 1-10 Date Received: 10/05/03 Grid Openings Analyzed: __ 4

Project Sample Nc.: SH£-l>10-10/5-14 Average Grid Opening: 105.OQ urn

Air Volume: 1853 iiCeis Total Arsa Analysed : 0^^4 5.0 jnr^

Filter Tvne; MCE 25 mm dian. Pore Size: 0.45 urn. -Analytical Sensitivity :^2r 2 3/mni2 Effective Area; 385 mm2 0-0046 s/cc

FIBxROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters struct. Struct > = 5um Struct/mm2 Struct/cc ncm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphioois Asbestos 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0.0 0.0000 0

Total asbe^stos (includes amoiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0 0 0 0 N7A

Totals (All Structures) 0 0 0.0 0 . ocoo N/.A The estimc.ted uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Anai lyzed by: Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO3473568 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248470

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248470Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244688

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

Similar indexed content

Compare copies and versions →