NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 40%

TEM asbestos identification and SAED/EDS for Stuyvesant HS, Oct 2001.

NYC-WTC_000248469
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1137 Long Island City, NY 11101 Report Date; 10/05/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy EDS) Method; A-IERA Final Rule, ERA Federal Register (40 CFR, Part ~63), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Si;e: Stuyvesant H.S., 34S Chambers St., NY, NY TEM Sample No.: 5609 60020 Floors 1 10 Date Rece.lved: 10/05/01. 3rid Openings Tknalyzed ;__ 4

Project Sample No.: SKS-l>10-10/5-15 Average Grid Gpenincf: 106.00 um

Air Volume: 1853 liters Total Area Analyzed 0.0453 mm2

Filter Ty^ie: MCE 25 mm diam , Pore Size: 0.45 um Analytical Sensitivity 22-2 s/'mm2 Effective Area: 535 mm3 0.0046 3/

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/rnm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . C'CGO 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0 . OOCO 0

Total asbestos ^includes araoiguous structures^ 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/.A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty c.: this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Ansi lyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO3473567 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248469

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248469Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →