NYC 9/11 Public Portal Document
ATC Environmental, Inc,
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: lO/29/Ol
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: A^ERA Final Rule. IIPA Federal Register (40 CFR, Part 763). Vol. 52, Ko. 210, October 30, 1967
Sample Identification Analysis Parameters
Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 62430
Exterior & Iritcsrior of auildinq & Roof
Date Received; 10/28/01 Grid Openings Analyzed;__ 4
Project Sample No.; 21 Average Grid Qpenin:?: 106.00 urn
Air Volume: 1944 liters Total Area Analyzed; 0.0450 nim2
Filter Tyoe: MCE 25 mm diaci. , Pore Size; 0.45 urn Analytical Sensitivity :22;2 s/intTi2
Effective Area; 365 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
S trig It; Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ncrm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0. D 0.0000 0
Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0
Total asbestos (includes anb.iguous structures) 0 0 0.0 0.0000 0
Non-Asbesto3 0 0 0 0 0 0 0. 0 0.0000 N/A
No Identification 0 0 0 0 0 0 0. C 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The .!inalysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473481