ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/29/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive XRAY Spectroscopy (EDS) Method: AHER-^ Final Rula, E?A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 - 62427 Exterior 2 Incerior of Building & Roof Date Received:iC/28/0i Grid Openings Analyzed;__ 4

Project Sample No. Average Grid Opening :^l 0 6^00 j£ri

Air Volume: 1944 liters Total Area Analyzed: 0.0450 miTi2

Filter Type: MCE 25 mm dram. Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2

Effective .Area-. 3 8 5 rnm2 0.0044 -s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ncjTn/m3

Chrysotile Asbestos 0 0 0 0 0 a 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 C.0 0.0000 0

Ambiguous 3 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Nor.-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A

No Identification 0 0 0 0 0 0 0.0 0.0000 N/'A

Totals (Ail Structures) 0 0 0.0 0 . 0000 N/A The estimated uncertainty c f this analysis is 1 standard deviation.

Non-asibestos fiber i.d. (EDS/SAED) : None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473478 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248386

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248386Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000292757

TEM analysis notes: exterior/interior of building and data parameters for 10/28/01.

Similar indexed content

NYC-WTC_000270810

TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.

Similar indexed content

NYC-WTC_000188708

Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.

Similar indexed content

NYC-WTC_000293862

TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant H.S.; received 10/23/01, analyzed 4.

Similar indexed content

NYC-WTC_000292755

TEM data: air volume, opening, and diffractive measurements for New Stuyvesant H.S., 10/28/01.

Similar indexed content

Compare copies and versions →