Asbestos TEM analysis, [site], Oct 1957

Machine-extracted title · confidence 25%

TEM asbestos analysis with SAED/EDS for project site, Oct 1957.

NYC-WTC_000248379
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/29/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Ident.ifacat.ion by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; 71HERA Final Rule, FKA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1957

Sample Ideintification Analysis Parameters

Project/Site: New Stuwesant H.5., 345 Chambers St., NY, NY TEM Sample No.: 5785 62419 Exterior <2 Interior of Building & Roof Date Rec€;ived Grid Openings Analyzed:__4

Project Sanple No.: 10 Average Grid Opening: 106.DO um

Air Volunie: 1928 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam.. Pore Size: 0.45 um Analytical Sensitivity:2^2 s2rrin^ Effective Areu: 385 mm2 0.0044 s/cc

FIBRO"JS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fiber.'; Bundles Clusters Struct. Struct > = 5um Stmct/rn’Ti2 Struct/cc narr./m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Nor.-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A Nc Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473470 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248379

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248379Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270879

TEM analysis; exterior/interior of building, sample 12.

Similar indexed content

NYC-WTC_000244757

TEM analysis; exterior of building; sample 5739; opening and air volume data.

Similar indexed content

NYC-WTC_000293856

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

Compare copies and versions →