NYC-WTC_000244376
TEM analysis with SAED/EDS; NSHS site data, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗TEM report, exterior/interior of New Stuyvesant HS building, Oct 28-29, 2001.
NYC-WTC_000248374OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NI'LAI Lab Code # 118 7 Long Island City, NY 11101 Report Date: 10/29/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction iSAED! and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, iPA Federal Register (40 CFR, Part 763), Vol. 52, No, 210, October 30, 2987
Sample Identification Analysis Parameters
Project/Sice: New Stuwesanr R. S. , 345 Chambers St., NY, NY TEM Sample No.: 5765 62414 Exterior S: Interior of Building & Roof Eate Received: 10/28/01 Grid Openings Analyzed;__4
Project Sample No.:_5 Average Grid Opening: 106.00 urn
Air Volums: 1920 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mrn diani. , Pore Size: 0.45 urn Analytical Sensitivity: 2 s/nim2 Effective Are<..: 365 mm2 0 ■ 0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total S.trgle Matrix Total. Struct. Filter Air F-berr Liimd’les Cl 11 «: .gt-rnr-r •> = Rnm Struct/rnm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 o.c 0.0000 0
Anbiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0. 0 0.0000 N7A No Identification c> 0 0 0 0 0 0. 0 0.0000 N/A
Totals (All Structures 0 0 0.0 0.0000 N/A The estimated uncertainty t-f this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Marek Peysakhcv Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473465 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000248374
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000244376
TEM analysis with SAED/EDS; NSHS site data, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270412
TEM asbestos analysis with SAED/EDS on New Stuyvesant HS, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244763
TEM asbestos analysis with SAED/EDS; project/site: high school exterior/interior details.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270872
TEM asbestos analysis, exterior & interior of building at New Stuyvesant HS.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293935
TEM analysis results for air samples at New Stuyvesant HS, exterior and interior, 10/25/01.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293500
TEM asbestos analysis for exterior/interior samples; New Stuyvesant High School; received 10/13/01.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293864
TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340297
TEM analysis with SAED and EDS identification for a high school project, 10/05/01
4 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270870
TEM asbestos fiber analysis at New Stuyvesant HS; project/site details and sample data.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330190
TEM asbestos analysis at HS for Economics & Finance, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248304
Asbestos TEM analysis with SAED/EDS for New Stuyvesant High School site, received 10/27/01.
4 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248381
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000244376
TEM analysis with SAED/EDS; NSHS site data, Oct 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270412
TEM asbestos analysis with SAED/EDS on New Stuyvesant HS, Oct 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244763
TEM asbestos analysis with SAED/EDS; project/site: high school exterior/interior details.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270872
TEM asbestos analysis, exterior & interior of building at New Stuyvesant HS.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293935
TEM analysis results for air samples at New Stuyvesant HS, exterior and interior, 10/25/01.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293500
TEM asbestos analysis for exterior/interior samples; New Stuyvesant High School; received 10/13/01.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000244376
TEM analysis with SAED/EDS; NSHS site data, Oct 2001.
Similar indexed content
TEM asbestos analysis with SAED/EDS on New Stuyvesant HS, Oct 2001.
Similar indexed content
NYC-WTC_000244763
TEM asbestos analysis with SAED/EDS; project/site: high school exterior/interior details.
Similar indexed content
TEM asbestos analysis, exterior & interior of building at New Stuyvesant HS.
Similar indexed content
TEM analysis results for air samples at New Stuyvesant HS, exterior and interior, 10/25/01.
Similar indexed content