NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM asbestos analysis, 5784, 10/28/01

Machine-extracted title · confidence 32%

TEM analysis of asbestos sample 5784; New Stuyvesant HS; exterior/interior; SAED/EDS; received 10/27/01; analyzed 10/28/01.

NYC-WTC_000248351
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELA? #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/28/01

ASBESTOS FIBER AISTALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber- Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDSi Method: AHERA Final Rule, E?A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S, 345 Chambers St., NY, NY TEM Sample No.: 57B4 62403

Exterior Sc Incerior of Building & Roof Date Received :l£/^2/01 Grid Openings Analyzed:__ 4

Project Sample No.: 18 Average Grid Opening: 106.00 um

Air Volume: 1928 liter Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm dram., Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2

Effective Aarea: 3 85 mm2 0■0044 S/CC

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibfsrs Bundles Clusters Struct, Struct >=5um Struct /mrr.2 StrucL/cc narn/n3

Chrysotile Asbestos 0 0 0 0 0 C.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0.0 0 . 0000 C

Ambiguous 0 0 0 0 0 c 0.0 0.0000 0

Total asb€;stos (includes ambiguous structures) 0 0 0.0 0.0000 0

Non-Asbest.os 0 0 0 0 0 0 0.0 0.oooo N/A

No Identification 0 0 0 0 0 0 0. 0 0.0000 N/A

Totals; (All Structures) 0 0 0.0 0 . 0000 N/A

The estimated uncertainty C'f this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473435 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248351

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248351Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270814

TEM asbestos analysis with SAED/EDS, New Stuyvesant High School.

Similar indexed content

NYC-WTC_000270764

TEM asbestos analysis with SAED/EDS; sample 5748-62071, exterior/interior.

Similar indexed content

NYC-WTC_000270877

TEM asbestos analysis; exterior/interior, sample 10.

Similar indexed content

NYC-WTC_000293820

TEM analysis of exterior/interior building samples; SAED/EDS; Received 10/22/01.

Similar indexed content

NYC-WTC_000270723

TEM analysis with SAED/EDS for New Stuyvesant High School, received 10/22/01.

Similar indexed content

Compare copies and versions →