NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/28/01
ASBESTOS FIBER ANALYSIS BY TRTINSMISSION ELECTRON MICROSCOPY (TEM)
With ribei' Identification ty Selected-Area Electron Diffraction (SAEDl and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: ARERA Final Rule, ERA Federal Register (40 CFR, Part 763)-, Vol. 52, No. 21C, October 30, 1987
Sample Idertificat.ion Analysis Parameters
Project/Site: New Stuyvesant H.S, 345 Chambers St., NY, NY TEM Sample No,: 57B4 62402
Exterior & Inferior of Building & Roof
Date Received:l£/27/01 Grid Openings Analyzed:__ 4
Project Somple No.: I? Average Grid Openinc: 106.00 um
Air Volume: 1936 liters Total Area Analyzed: 0.0450 Tnm2
Filter Type; MCE 25 mm diam,, Pore Size: 0.45 um Analytical Sensitivity :22;J S2J7im2
Effective Area: 385 mm2 0 ■ 0044 S/'cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total - Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/nim2 Struct/cc nam/m3
Chrysotile; Jisbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 C.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includ6:s an higuous structures) 0 c 0.0 0. 0000 0
Non-Asbestos 0 0 0 0 0 c 0.0 0.0000 N/A
No Ide;nti::icaticin 0 0 0 0 0 0 0.0 0.0000 N/'A
Totals (All Structures) 0 0 0.0 0 . 0000 N/A
The estimated uncertainty C'f this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC1OO_OO3473434
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000248350