TEM asbestos analysis, 62356, Oct 2001

Machine-extracted title · confidence 32%

TEM analysis of asbestos sample 62356 by ATC Associates for Education Dept; Oct 2001.

NYC-WTC_000248344
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/28/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHEPJi Final Rule, EP/x Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Ident-fication Analysis Parameters

Project/Site: New Stuyvesant H.S, 345 Chambers St., NY, NY TEM Sample No.; 5784 62396 Exterior & Intsirior of Building & Roof Date Received; 10/27/0] Grid Openings Analyzed:__4

Project Sample No.: 11 Average Grid Opening: 106.00 urn

Air Volume 1944 liters Total Area Analyzed •.^;.045Cb ILIL2

Filter Ty^ie . MCE 25 mm dian . , Pore Size: 0.45 urn Analytical Sensitivity:.22;^s2>™il2 Effective Aiea: 385 mm2 0.C044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers' Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqrr./m3

Chrysotil'2 Asbestos c 0 0 0 0 0 0. 0 0.0900 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 c

Ambiguous 0 0 G 0 0 0 0.0 0.0000 0

Total asbestos (includes aribxguous structures) 0 0 0.0 0.0000 c Non-Asbes-os 0 0 0 0 0 0 0.0 0.0000 K/A No Identification 0 0 0 0 0 0 0.0 0.0000 K/A

Totals (Ail Structures' 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473428 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248344

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248344Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000294022

TEM-based asbestos identification and SAED/EDS for exterior & interior samples at New Stuyvesant H.S.

Similar indexed content

NYC-WTC_000270670

TEM analysis of asbestos fibers at New Stuyvesant H.S. with SAED/EDS, Oct 2001.

Similar indexed content

NYC-WTC_000293901

TEM data with air volume and analysis parameters for building sample.

Similar indexed content

NYC-WTC_000292755

TEM data: air volume, opening, and diffractive measurements for New Stuyvesant H.S., 10/28/01.

Similar indexed content

NYC-WTC_000294023

TEM analysis of asbestos fibers from New Stuyvesant High School project samples.

Similar indexed content

Compare copies and versions →