NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/28/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identificattcn by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: ANEPA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Projecc/Site: Nev Stuyvesant E.S, 345 Chambers St., NY, NY TEM Sample No. : 5*784 62395
Exterior & Interior of Building & Roof
Date deceived: 10/27/01 3rid Openings Analyzed:__ 4
Project Sample No.: 10 Average Grid Opening: 106,00 urn
Air Volume : 1923 1J^^rs Total Area Analyzed .■ C. 045U rrn)2
Filter Tyj)e: MCE 25 mm diarr . , Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2
Effective Aree: 385 mm2 0.0044 S/CC
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Buncles Clusters Struct,Struc^ > = 5um Struct ''mni2 Struct/cc nqm/m3
Chrysotile! Asbestos 0 0 0 0 0 C 0.0 0.0000 C
Amphibole Asbestos 0 0 0 0 0 c 0.0 0.0000 0
Ambiguous 0 0 0 0 0 ‘ G 0.0 0.0000 c
Total asbcistos (Includes atibiguous structures) 0 0 0.0 0.0000 0
Non-Asbes :o.'= 0 c 0 0 C 0.0 0.0000 N/A
No IdentiCication 0 0 c 0 0 c 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estiniited uncertainty C'f this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473427
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000248343