Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 24%

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., exterior/interior of building, received 10/27/01.

NYC-WTC_000248319
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/27/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber _dentification ny .Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RJlY Spectroscopy (EDS'! Method: AHERA Final Rule. EPA Federal Register (40 CFR. Part 763), Vol. 52, No. 210, October 30, 1987

Sample IdentifLcazicn Analysis Parameters

Pl-Oj ecu,'Site: Ney Stuwesant H.S.. 34S Chambers St., NY, NY TEM Sample No.: 5775 62378 Exterior & Interior of Building & Roof Date Recfe'ived ; 10/2£^ Grid Openings Analyzed:__ 4

Project S.ample Ho. : 17 Average Grid Opening :Jn06;0C un)

Air Volume: 1936 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 inn dlam. . Pore Size: 0.45 urn Analytical Sens i t i v i t y.- 22. z s/mm2 Effective Aiea: 385 mm2 0.00^4

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5uni Struct/irm? Struct/cc nam/ra3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Amphibole’ Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0 . 0000 0

Total asbestos (includes ambiguous structures) 0 0 0.c 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 C . 0000 N/A No Identification 0 0 0 0 0 0 0.0 c.oooo N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by.-

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473390 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248319

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248319Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000274164

TEM asbestos analysis; New Stuyvesant HS, sample 5758-62154, received 10/24/01.

Similar indexed content

NYC-WTC_000248307

TEM asbestos analysis with diffraction/EDS, New Stuyvesant High School site, 10/27/01.

Similar indexed content

NYC-WTC_000248381

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000293864

TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.

Similar indexed content

Compare copies and versions →